The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Voltage Stabilization in Microgrids via Quadratic Droop Control
Open accessAbstract
We consider the problem of voltage stability and reactive power balancing in islanded small-scale electrical networks outfitted with DC/AC inverters (“microgrids”). A droop-like voltage feedback controller is proposed which is quadratic in the local voltage magnitude, allowing for the application of circuit-theoretic analysis techniques to the closed-loop system. Under our design, the operating points of the closed-loop microgrid are in exact correspondence with the solutions of a reduced power flow equation, and we provide explicit solutions and small-signal stability analyses under several static and dynamic load models. Controller optimality is characterized as follows: we show a one-to-one correspondence between the high-voltage equilibrium of the microgrid under quadratic droop control, and the solution of an optimization problem which minimizes a trade-off between reactive power dissipation and voltage deviations. Power sharing performance of the controller is characterized as a function of the controller gains, network topology, and parameters. Proportional sharing of the total load between inverters is achieved in a low-gain limit, independent of the circuit topology or reactances. All results hold for arbitrary grid topologies, with arbitrary numbers of inverters and loads. Numerical results confirm the robustness of the controller to unmodeled dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 2×
“As a flexible bridge between distributed generators and larger distribution grids, microgrids continue to attract attention [1]–[3].”
Background
Cited by
A Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273
Self-citationOn the Secondary Control Architectures of AC Microgrids: An Overview
Khayat, Y., Shafiee, Q., Heydari, R., Naderi, M., Dragicevic, T., Simpson-Porco, J. W., Dorfler, F., Fathi, M., Blaabjerg, F., Guerrero, J. M., et al. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2951694 · Cited by 385
Self-citationUnderstanding Small-Signal Stability of Low-Inertia Systems
Markovic, U., Stanojev, O., Aristidou, P., Vrettos, E., Callaway, D., & Hug, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3061434 · Cited by 370
A survey on control issues in renewable energy integration and microgrid
Badal, F. R., Das, P., Sarker, S. K., & Das, S. K. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0122-8 · Cited by 357
Distributed Cooperative Optimal Control of DC Microgrids With Communication Delays
Ding, L., Han, Q.-L., Wang, L. Y., & Sindi, E. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2799239 · Cited by 295
Metadata
- Authors
- Simpson-Porco, J. W., Dorfler, F., & Bullo, F.
- Venue
- IEEE Transactions on Automatic Control
- Published
- 2017-03
- Volume
- 62
- Issue
- 3
- Pages
- 1239-1253
- ISSN
- 0018-9286 (ISSN-L)
- 1558-2523
- OpenAlex
- W2030267180
- Cited by
- 166
- References
- 2
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.