The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A Frequency Control Method for Regulating Wireless Power to Implantable Devices
Abstract
This paper presents a method to regulate the power transferred over a wireless link by adjusting the resonant operating frequency of the primary converter. A significant advantage of this method is that effective power regulation is maintained under variations in load, coupling and circuit parameters. This is particularly important when the wireless supply is used to power implanted medical devices where substantial coupling variations between internal and external systems is expected. The operating frequency is changed dynamically by altering the effective tuning capacitance through soft switched phase control. A thorough analysis of the proposed system has been undertaken, and experimental results verify its functionality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
10 kHz inductively coupled power transfer - concept and control
Green, A. W. (1994) · Proceedings of 5th International Conference on Power Electronics and Variable-Speed Drives · doi:10.1049/cp:19941049 · Cited by 300
Powering an Artificial Heart: Birth of the Inductively Coupled–Radio Frequency System in 1960
Schuder, J. C. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.07130.x · Cited by 106
Selected resonant converters for IPT power supplies
Hu, A. P. (2001) · ResearchSpace (University of Auckland) · Cited by 105
Self-citationWireless Power Supply for Implantable Biomedical Device Based on Primary Input Voltage Regulation
Si, P., Hu, A. P., Hsu, J.-U. W., Chiang, M., Wang, Y., Malpas, S. C., & Budgett, D. (2007) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2007.4318406 · Cited by 101
Self-citationSanders, R., & Lee, M. T. (1996) · Proceedings of the IEEE · doi:10.1109/5.486749 · Cited by 90
(2009) · Biomedical Safety & Standards · doi:10.1097/01.bmsas.0000357950.23926.eb · Cited by 58
An implantable telemetry system powered by a capacitor having high capacitance
Maki, H., Yonezawa, Y., Harada, E., & Ninomiya, I. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746980 · Cited by 6
Cited by
Wireless Power Transfer—An Overview
Zhang, Z., Pang, H., Georgiadis, A., & Cecati, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835378 · Cited by 1,723
Modern Trends in Inductive Power Transfer for Transportation Applications
Covic, G. A., & Boys, J. T. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2264473 · Cited by 1,263
Covic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223
Li, H., Li, J., Wang, K., Chen, W., & Yang, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2349534 · Cited by 592
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Metadata
- Authors
- Si, P., Hu, A. P., Malpas, S., & Budgett, D.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2008-03
- Volume
- 2
- Issue
- 1
- Pages
- 22-29
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2103357789
- Cited by
- 582
- References
- 9
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.