A Frequency Control Method for Regulating Wireless Power to Implantable Devices
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper presents a method to regulate the power transferred over a wireless link by adjusting the resonant operating frequency of the primary converter. A significant advantage of this method is that effective power regulation is maintained under variations in load, coupling and circuit parameters. This is particularly important when the wireless supply is used to power implanted medical devices where substantial coupling variations between internal and external systems is expected. The operating frequency is changed dynamically by altering the effective tuning capacitance through soft switched phase control. A thorough analysis of the proposed system has been undertaken, and experimental results verify its functionality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
10 kHz inductively coupled power transfer - concept and control
Green, A. W. (1994) · Proceedings of 5th International Conference on Power Electronics and Variable-Speed Drives · doi:10.1049/cp:19941049 · Cited by 300
Powering an Artificial Heart: Birth of the Inductively Coupled–Radio Frequency System in 1960
Schuder, J. C. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.07130.x · Cited by 106
Selected resonant converters for IPT power supplies
Hu, A. P. (2001) · ResearchSpace (University of Auckland) · Cited by 105
Self-citationWireless Power Supply for Implantable Biomedical Device Based on Primary Input Voltage Regulation
Si, P., Hu, A. P., Hsu, J. W., Chiang, M., Wang, Y., Malpas, S., & Budgett, D. (2007) · 2007 2nd IEEE Conference on Industrial Electronics and Applications · doi:10.1109/iciea.2007.4318406 · Cited by 101
Self-citationSanders, R. S., & Lee, M. T. (1996) · Proceedings of the IEEE · doi:10.1109/5.486749 · Cited by 71
(2009) · Biomedical Safety & Standards · doi:10.1097/01.bmsas.0000357950.23926.eb · Cited by 58
An implantable telemetry system powered by a capacitor having high capacitance
Maki, H., Yonezawa, Y., Harada, E., & Ninomiya, I. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746980 · Cited by 6
Cited by
Wireless Power Transfer—An Overview
Zhang, Z., Pang, H., Georgiadis, A., & Cecati, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835378 · Cited by 1,723
Modern Trends in Inductive Power Transfer for Transportation Applications
Covic, G. A., & Boys, J. T. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2264473 · Cited by 1,263
“For charging applications where there is one supply for each coupled load, there is a tendency to operate using only primary side control [84]–[86].”
BackgroundCovic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223
Li, H., Li, J., Wang, K., Chen, W., & Yang, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2349534 · Cited by 592
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Primary-Side Power Flow Control of Wireless Power Transfer for Electric Vehicle Charging
Miller, J. M., Onar, O. C., & Chinthavali, M. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2382569 · Cited by 533
A High Efficiency 5 kW Inductive Charger for EVs Using Dual Side Control
Wu, H. H., Gilchrist, A., Sealy, K. D., & Bronson, D. (2012) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2192283 · Cited by 512
A Unity-Power-Factor IPT Pickup for High-Power Applications
Keeling, N. A., Covic, G. A., & Boys, J. T. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027255 · Cited by 371
Song, K., Li, Z., Jiang, J., & Zhu, C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2767099 · Cited by 337
Li, W., Zhao, H., Li, S., Deng, J., Kan, T., & Mi, C. C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2384003 · Cited by 331
Hybrid Bidirectional Wireless EV Charging System Tolerant to Pad Misalignment
Zhao, L., Thrimawithana, D. J., & Madawala, U. K. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686301 · Cited by 328
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315
Miller, J. M., Onar, O. C., White, C., Campbell, S., Coomer, C., Seiber, L., Sepe, R., & Steyerl, A. (2014) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2014.2300978 · Cited by 256
Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 246
Qu, X., Jing, Y., Han, H., Wong, S.-C., & Tse, C. K. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2535376 · Cited by 216
Shi, Q., Wang, T., & Lee, C. (2016) · Scientific Reports · doi:10.1038/srep24946 · Cited by 210
Zhang, X., Cai, T., Duan, S., Feng, H., Hu, H., Niu, J., & Chen, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2871794 · Cited by 206
“2871794 Applications of IPT range from low-power systems, such as portable electronic devices [1], [2], biomedical plant [3], [4],”
BackgroundEnabling Seamless Wireless Power Delivery in Dynamic Environments
Sample, A. P., Waters, B. H., Wisdom, S. T., & Smith, J. R. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2252453 · Cited by 191
“After converting the lumped ABCD-matrix back to an S-matrix, the source and load capacitor values in each -match network are determined by selecting values that optimize jS21j at the desired frequency.”
MethodGeneralized Active EMF Cancel Methods for Wireless Electric Vehicles
Choi, S. Y., Gu, B. W., Lee, S. W., Lee, W. Y., Huh, J., & Rim, C. T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295094 · Cited by 184
“W IRELESS power has been increasingly used in mobile devices [1]–[4], industry clean rooms [5]–[7], medical applications [8]–[10], and electrified transportations [11]–[46]”
BackgroundPractical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial
Schormans, M., Valente, V., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2846020 · Cited by 170
Internal illumination of photobioreactors via wireless light emitters: a proof of concept
Heining, M., Sutor, A., Stute, S. C., Lindenberger, C. P., & Buchholz, R. (2015) · Journal of Applied Phycology · doi:10.1007/s10811-014-0290-x · Cited by 76
“This system is applied, for example, in powering cochlear implants or pacemakers (Si et al. 2008; Villa et al. 2009).”
BackgroundMethod
Metadata
- Authors
- Si, P., Hu, A. P., Malpas, S., & Budgett, D.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2008-03
- Volume
- 2
- Issue
- 1
- Pages
- 22-29
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2103357789
- Cited by
- 582
- References
- 9
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.