The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Open accessAbstract
A remotely powered implantable microsystem for continuous blood glucose monitoring is presented. The microsystem consists of a microfabricated glucose biosensor flip-chip bonded to a transponder chip. The transponder chip is inductively powered by an external reader with a 13.56-MHz carrier. It then measures the output signal of the glucose biosensor and transmits the measured data back to the external reader using load-shift keying (LSK). The microsystem has a volume of 32 mm(3). The procedures for the microfabrication of the glucose sensor and the assembly of the microsystem are described along with the description of the circuit blocks of the transponder chip. The transponder chip has been fabricated with the TSMC 0.18-mum CMOS process and has a total area of 1.3 x 1.3 mm(2). The chip can measure the sensor output current ranging from 1 nA to 1 muA with less than 0.3% nonlinearity error, provided that the amplitude of the received RF signal is higher than 2.6 V; the circuit consumes a total current of about 110 muA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,822
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
A CMOS bandgap reference circuit with sub-1-V operation
Banba, H., Shiga, H., Umezawa, A., Miyaba, T., Tanzawa, T., Atsumi, S., & Sakui, K. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.760378 · Cited by 908
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Fully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Physiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 251
Akin, T., Najafi, K., & Bradley, R. M. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.654942 · Cited by 207
Glucose monitoring: state of the art and future possibilities
Wilkins, E., & Atanasov, P. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00046-1 · Cited by 180
Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.2005927 · Cited by 179
Self-citationBiosensors: Fundamentals and applications
Bannister, J. V. (1987) · Biosensors · doi:10.1016/0265-928x(87)80005-6 · Cited by 165
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135
VLSI Potentiostat Array With Oversampling Gain Modulation for Wide-Range Neurotransmitter Sensing
Stanaćević, M., Murari, K., Rege, A., Cauwenberghs, G., & Thakor, N. V. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893176 · Cited by 129
A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors
Shults, M. C., Rhodes, R. K., Updike, S. J., GILLIGAN, B. J., & Reining, W. N. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.324525 · Cited by 113
16-Channel Integrated Potentiostat for Distributed Neurochemical Sensing
Genov, R., Stanaćević, M., Naware, M., Cauwenberghs, G., & Thakor, N. V. (2006) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2006.884425 · Cited by 99
Evaluation of a Subcutaneous Glucose Sensor out to 3 Months in a Dog Model
GILLIGAN, B. J., Shults, M. C., Rhodes, R. K., & Updike, S. J. (1994) · Diabetes Care · doi:10.2337/diacare.17.8.882 · Cited by 90
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71
Integrated implantable device for long-term glucose monitoring
Wilkins, E. S., Atanasov, P., & Muggenburg, B. A. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96894-5 · Cited by 68
An integrated CMOS potentiostat for miniaturized electroanalytical instrumentation
Reay, R. J., Kounaves, S. P., & Kovacs, G. T. A. (2002) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.1994.344686 · Cited by 65
Zimmermann, S., Fienbork, D., Stoeber, B., Flounders, A. W., & Liepmann, D. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1215262 · Cited by 63
A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors
Bd, M., & Gough, D. A. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4581 · Cited by 56
Frequency Characterization of Blood Glucose Dynamics
Gough, D. A., Kreutz-Delgado, K., & Bremer, T. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1535411 · Cited by 47
Glucose detection based on electrochemically formed Ir oxide films
Abu‐Irhayem, E., Elżanowska, H., Jhas, A. S., Skrzynecka, B., & Birss, V. I. (2002) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(02)01142-7 · Cited by 40
Kvist, P. H., Iburg, T. M., Aalbæk, B., Gerstenberg, M., Schoier, C., Kaastrup, P., Buch‐Rasmussen, T., Hasselager, E., & Jensen, H. E. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.546 · Cited by 39
A very low power CMOS potentiostat for bioimplantable applications
Ahmadi, M. M., & JULLIEN, G. A. (2005) · International Workshop on System-on-Chip for Real-Time Applications · doi:10.1109/iwsoc.2005.32 · Cited by 38
Self-citationThe role of continuous glucose sensors in diabetes care
Garg, S. K., Hoff, H. K., & Chase, H. P. (2004) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2004.01.001 · Cited by 32
Implantation of a refillable glucose monitoring-telemetry device
Atanasov, P., Yang, S., Salehi, C., Ghindilis, A. L., Wilkins, E. S., & Schade, D. S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00025-0 · Cited by 32
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315
Convolutional Recurrent Neural Networks for Glucose Prediction
Li, K., Daniels, J., Liu, C., Herrero, P., & Georgiou, P. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2908488 · Cited by 310
Metadata
- Authors
- Ahmadi, M. M., & Jullien, G. A.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2009-06
- Volume
- 3
- Issue
- 3
- Pages
- 169-180
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2164989510
- Cited by
- 266
- References
- 31
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.