A Battery-Free Multichannel Digital Neural/EMG Telemetry System for Flying Insects
Abstract
This paper presents a digital neural/EMG telemetry system small enough and lightweight enough to permit recording from insects in flight. It has a measured flight package mass of only 38 mg. This system includes a single-chip telemetry integrated circuit (IC) employing RF power harvesting for battery-free operation, with communication via modulated backscatter in the UHF (902-928 MHz) band. An on-chip 11-bit ADC digitizes 10 neural channels with a sampling rate of 26.1 kSps and 4 EMG channels at 1.63 kSps, and telemeters this data wirelessly to a base station. The companion base station transceiver includes an RF transmitter of +36 dBm (4 W) output power to wirelessly power the telemetry IC, and a digital receiver with a sensitivity of -70 dBm for 10⁻⁵ BER at 5.0 Mbps to receive the data stream from the telemetry IC. The telemetry chip was fabricated in a commercial 0.35 μ m 4M1P (4 metal, 1 poly) CMOS process. The die measures 2.36 × 1.88 mm, is 250 μm thick, and is wire bonded into a flex circuit assembly measuring 4.6 × 6.8 mm.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Such recording systems are often powered by small lightweight batteries or by wireless power transfer.
“Often, such systems are powered using miniaturized and light-weight battery packs [36] or wireless power transfer systems [135].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [135]
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Self-citationA review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372 · see citing works
Fully integrated passive uhf rfid transponder ic with 16.7-μ minimum rf input power
Karthaus, U., & Fischer, M. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.817249 · Cited by 856 · see citing works
Communication by Means of Reflected Power
Stockman, H. (1948) · Proceedings of the IRE · doi:10.1109/jrproc.1948.226245 · Cited by 732 · see citing works
Complete Link Budgets for Backscatter-Radio and RFID Systems
Griffin, J. D., & Durgin, G. D. (2009) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2009.5162013 · Cited by 557 · see citing works
Design criteria for the RF section of UHF and microwave passive RFID transponders
Vita, G. D., & Iannaccon, G. (2005) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2005.854229 · Cited by 424 · see citing works
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330 · see citing works
Self-citationPrey pursuit and interception in dragonflies
Olberg, R. M., Worthington, A. H., & Venator, K. R. (2000) · Journal of Comparative Physiology A · doi:10.1007/s003590050015 · Cited by 290 · see citing works
Low-Power CMOS Rectifier Design for RFID Applications
Mandal, S., & Sarpeshkar, R. (2007) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2007.895229 · Cited by 272 · see citing works
Relationships between antennas as scatterers and as radiators
Hansen, R. C. (1989) · Proceedings of the IEEE · doi:10.1109/5.32056 · Cited by 258 · see citing works
Nikitin, P., Rao, K. V., & Martínez, R. (2007) · Electronics Letters · doi:10.1049/el:20070253 · Cited by 246 · see citing works
Wireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 220 · see citing works
A wireless multi-channel neural amplifier for freely moving animals
Szuts, T. A., Fadeyev, V., Kachiguine, S., Sher, A., Grivich, M., Agrochão, M., Hottowy, P., Dąbrowski, W., Lubenov, E. V., Siapas, A. G., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2730 · Cited by 183 · see citing works
Analytical Approach to the Backscattering from UHF RFID Transponder
Fuschini, F., Piersanti, C., Paolazzi, F., et al. (2008) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2007.914121 · Cited by 156 · see citing works
Identified target-selective visual interneurons descending from the dragonfly brain
Olberg, R. M. (1986) · Journal of Comparative Physiology A · doi:10.1007/bf00603736 · Cited by 108 · see citing works
A 9 $\mu$A, Addressable Gen2 Sensor Tag for Biosignal Acquisition
Yeager, D. J., Zhang, F., Zarrasvand, A., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2063930 · Cited by 105 · see citing works
Wireless Neural/EMG Telemetry Systems for Small Freely Moving Animals
Harrison, R. R., Fotowat, H., Chan, R., Kier, R. J., Olberg, R. M., Leonardo, A. M., & Gabbiani, F. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2131140 · Cited by 92 · see citing works
Self-citationNieder, A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00263-6 · Cited by 69 · see citing works
Takeuchi, S., & Shimoyama, I. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820310 · Cited by 64 · see citing works
Ando, N., Shimoyama, I., & Kanzaki, R. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00013-4 · Cited by 60 · see citing works
Wireless Transmission of Muscle Potentials During Free Flight of a Locust
Kutsch, W., Schwarz, G., Fischer, H., et al. (1993) · Journal of Experimental Biology · doi:10.1242/jeb.185.1.367 · Cited by 48 · see citing works
A VLSI Neural Monitoring System With Ultra-Wideband Telemetry for Awake Behaving Subjects
Greenwald, E., Mollazadeh, M., Hu, C., Tang, W., Culurciello, E., & Thakor, N. V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2141670 · Cited by 48 · see citing works
Fischer, H., Kautz, H., & Kutsch, W. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00083-6 · Cited by 47 · see citing works
Hampson, R. E., Collins, V., & Deadwyler, S. A. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.007 · Cited by 46 · see citing works
An ultralight biotelemetry backpack for recording EMG signals in moths
Mohseni, P., Nagarajan, K., Ziaie, B., et al. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.923792 · Cited by 37 · see citing works
Single-ended ultra-low-power multistage rectifiers for passive RFID tags at UHF and microwave
Seemann, K., Hofer, G., Cilek, F., et al. (2006) · IEEE Radio and Wireless Symposium (RWS) · doi:10.1109/rws.2006.1615199 · Cited by 20 · see citing works
A radiotelemetry system for muscle potential recordings from freely flying insects
Kuwana, Y., Ando, N., Kanzaki, R., et al. (2003) · doi:10.1109/iembs.1999.804001 · Cited by 14 · see citing works
Power feasibility of implantable digital spike-sorting circuits for neural prosthetic systems
Zumsteg, Z. S., Ahmed, R. E., Santhanam, G., et al. (2005) · doi:10.1109/iembs.2004.1404181 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · see citing works
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
How animals glide: from trajectory to morphology
Socha, J. J., Jafari, F., Munk, Y., & Byrnes, G. (2015) · Canadian Journal of Zoology · doi:10.1139/cjz-2014-0013 · Cited by 65 · see citing works
EnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62 · see citing works
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25 · see citing works
- Authors
- Thomas, S. J., Harrison, R. R., Leonardo, A., & Reynolds, M. S.
- Affiliations
- Duke University (US)
- Intan Technologies (United States) (US)
- Howard Hughes Medical Institute (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-10
- Volume
- 6
- Issue
- 5
- Pages
- 424-436
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2062807339
- Cited by
- 117
- References
- 28
- Citations by year
- 2026: 3 · 2025: 22 · 2024: 4 · 2023: 6 · 2022: 5 · 2021: 13 · 2020: 5 · 2019: 11 · 2018: 4 · 2017: 9 · 2016: 9 · 2015: 8 · 2014: 11 · 2013: 5 · 2012: 1
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Howard Hughes Medical Institute
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- electromyography, battery-free operation, RF energy harvesting, backscatter communication, UHF band, on-chip ADC, insect neurophysiology
- MeSH terms
- Amplifiers, Electronic, Animals, Biomedical Engineering, Electromyography, Equipment Design, Flight, Animal, Interneurons, Electric Power Supplies, Signal Processing, Computer-Assisted, Telemetry, Wireless Technology, Odonata
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review