Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Wireless power transfer systems, particularly those based on inductive coupling, provide an increasingly attractive method to safely deliver power to biomedical implants. Although there exists a large body of literature describing the design of inductive links, it generally focuses on single aspects of the design process. There is a variety of approaches, some analytic, some numerical, each with benefits and drawbacks. As a result, undertaking a link design can be a difficult task, particularly for a newcomer to the subject. This tutorial paper reviews and collects the methods and equations that are required to design an inductive link for biomedical wireless power transfer, with a focus on practicality. It introduces and explains the published methods and principles relevant to all aspects of inductive link design, such that no specific prior knowledge of inductive link design is required. These methods are also combined into a software package (the Coupled Coil Configurator), to further simplify the design process. This software is demonstrated with a design example, to serve as a practical illustration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878 · cited 2×
“1) Constraints and Calculations: Typical cochlear implants require around 40 mW of power at the receiver, to be delivered through the skull by small coils aligned with a permanent magnet [96].”
BackgroundWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 1×
“In the case of extremely compact coils [27], [81], the equations will progressively lose accuracy as r0 approaches r.”
BackgroundCharthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245 · cited 2×
“The wide range of today’s implantable devices, including pacemakers, cochlear implants, and neurostimulators, adopt a similarly wide variety of WPT methods, including inductively coupled power transfer (ICPT) [7]–[13], ultrasonic power transfer (UPT) [17], [18], and capacitively coupled power transfer (CCPT) [19]–[21].”
BackgroundModeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241 · cited 5×
“Jow and Ghovanloo [31] consider a detailed model of PCB based spiral coils, but the analysis is not immediately applicable to wirewound coils.”
BackgroundMethodInfluential
Cited by
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“Schormans and collaborators [27] defined a table of expressions to extract the electrical parameters and to predict the electrical performances of the IPT link.”
BackgroundNear-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Pahlavan, S., Shooshtari, M., Maleki, M., & Jafarabadi Ashtiani, S. (2022) · Electronics · doi:10.3390/electronics11081204 · Cited by 20
Jiang, D., Wu, Y., Almarri, N., Habibollahi, M., Liu, F., Bryson, J. B., Greensmith, L., & Demosthenous, A. (2021) · 2021 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas51556.2021.9401220 · Cited by 11
“The implant consists of the bidirectional stimulator ASIC, 470-nm blue micro-LED arrays for optical stimulation, electrode arrays for electrical stimulation and electrophysiological recording, a wireless transceiver for communicating with the implant during operation, and the receiving side of an inductive link for wi…”
MethodSelf-citation
Metadata
- Authors
- Schormans, M., Valente, V., & Demosthenous, A.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-10
- Volume
- 12
- Issue
- 5
- Pages
- 1112-1130
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2883428425
- Cited by
- 170
- References
- 4
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial. https://app.cochat.ai/papers/10.1109/tbcas.2018.2846020
- The paper
- Schormans, M., Valente, V., & Demosthenous, A. (2018). Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2018.2846020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.