Abstract
Developing new tools to better understand disorders of the nervous system, with a goal to more effectively treat them, is an active area of bioelectronic medicine research. Future tools must be flexible and configurable, given the evolving understanding of both neuromodulation mechanisms and how to configure a system for optimal clinical outcomes. We describe a system, the Summit RC+S "neural coprocessor," that attempts to bring the capability and flexibility of a microprocessor to a prosthesis embedded within the nervous system. This paper describes the updated system architecture for the Summit RC+S system, the five custom integrated circuits required for bi-directional neural interfacing, the supporting firmware/software ecosystem, and the verification and validation activities to prepare for human implantation. Emphasis is placed on design changes motivated by experience with the CE-marked Activa PC+S research tool; specifically, enhancement of sense-stim performance for improved bi-directional communication to the nervous system, implementation of rechargeable technology to extend device longevity, and application of MICS-band telemetry for algorithm development and data management. The technology was validated in a chronic treatment paradigm for canines with naturally occurring epilepsy, including free ambulation in the home environment, which represents a typical use case for future human protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
A Comparison of Continuous Thalamic Stimulation and Thalamotomy for Suppression of Severe Tremor
Schuurman, P. R., Bosch, D. A., Bossuyt, P. M. M., Bonsel, G. J., van Someren, E. J. W., de Bie, R. M. A., Merkus, M. P., & Speelman, J. D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420703 · Cited by 1,044 · cited 1×
“WHILE implantable systems exist today that modulate the nervous system for treatment of neurological disorders [1]–[3], there is still a need for advancing neurotechnology to better serve patient populations with improved outcomes [4].”
Pallidal Deep-Brain Stimulation in Primary Generalized or Segmental Dystonia
Kupsch, A., Benecke, R., Müller, J., Trottenberg, T., Schneider, G.-H., Poewe, W., Eisner, W., Wolters, A., Müller, J.-U., Deuschl, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa063618 · Cited by 1,023 · cited 1×
“months for the physiological changes to fully emerge [18].”
Long-term efficacy and safety of thalamic stimulation for drug-resistant partial epilepsy
Salanova, V., Witt, T., Worth, R., Henry, T. R., Gross, R. E., Nazzaro, J. M., Labar, D., Sperling, M. R., Sharan, A., Sandok, E., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001334 · Cited by 821 · cited 1×
“WHILE implantable systems exist today that modulate the nervous system for treatment of neurological disorders [1]–[3], there is still a need for advancing neurotechnology to better serve patient populations with improved outcomes [4].”
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554 · cited 2×
“While the current examples describe brainbased systems, the potential applications of a neural coprocessor also extend into the periphery and organ systems [5], [14], [15].”
Adaptive deep brain stimulation for Parkinson’s disease using motor cortex sensing
Swann, N. C., de Hemptinne, C., Thompson, M. C., Miocinovic, S., Miller, A. M., Gilron, R., Ostrem, J. L., Chizeck, H. J., & Starr, P. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aabc9b · Cited by 389 · cited 1×
“These recordings feed into a database for continuous algorithm refinement [20].”
A Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372 · cited 1×
“Compared to many tools, the Summit RC+S system has limited channel count, most notably systems arising from the DARPA SUB-NETS and RAM programs [34], [35].”
Deep brain stimulation creates an informational lesion of the stimulated nucleus
Grill, W. M., Snyder, A. N., & Miocinovic, S. (2004) · NeuroReport · doi:10.1097/00001756-200405190-00011 · Cited by 369 · cited 1×
“The neural coprocessor framework seeks to advance from the historical concept of neuromodulation replacing a surgical lesion with a “stimulation lesion [7]” to the concept of designing a prosthetic system that provides adaptable, dynamic therapy to augment or regulate unhealthy neural circuits.”
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330 · cited 4×
“A comparison of the Summit RC+S to other research tools [16], [34]–[51] is captured in Table IV, which is an exten-”
InfluentialSelf-citation
Cited by
Gilron, R., Little, S., Perrone, R., Wilt, R., de Hemptinne, C., Yaroshinsky, M. S., Racine, C. A., Wang, S. S., Ostrem, J. L., Larson, P. S., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00897-5 · Cited by 343
Self-citationSchmidt, R., Herrojo Ruiz, M., Kilavik, B. E., Lundqvist, M., Starr, P. A., & Aron, A. R. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.1163-19.2019 · Cited by 338
Dual threshold neural closed loop deep brain stimulation in Parkinson disease patients
Velisar, A., Syrkin-Nikolau, J., Blumenfeld, Z., Trager, M. H., Afzal, M. F., Prabhakar, V., & Bronte-Stewart, H. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.02.020 · Cited by 252
Adaptive Deep Brain Stimulation: From Experimental Evidence Toward Practical Implementation
Neumann, W., Gilron, R., Little, S., & Tinkhauser, G. (2023) · Movement Disorders · doi:10.1002/mds.29415 · Cited by 189
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“implanted wireless BCIs have been developed [57]–[59].”
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“Some limited processing is embedded in recently developed neuromodulation devices, but this applies to 1–4 channels only, requiring external classifiers for more accurate symptom detection [71].”
BackgroundInfluentialAlgorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
“In 2018, an upgraded version, Summit RC+S [58], was intro-”
Background
Metadata
- Authors
- Stanslaski, S., Herron, J., Chouinard, T., Bourget, D., Isaacson, B., Kremen, V., Opri, E., Drew, W., Brinkmann, B. H., Gunduz, A., Adamski, T., Worrell, G. A., & Denison, T.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-12
- Volume
- 12
- Issue
- 6
- Pages
- 1230-1245
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2899579807
- Cited by
- 191
- References
- 46
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.