Cited by 25Photoacoustic and Ultrasonic ImagingOptical Imaging and Spectroscopy TechniquesNon-Invasive Vital Sign Monitoring

Toward wearable healthcare: a miniaturized 3d imager with coherent frequency-domain photoacoustics

Liu, Siyu, Tang, Kai, Feng, Xiaohua, Jin, Haoran, Gao, Fei, Zheng, Yuanjin·2019·IEEE Transactions on Biomedical Circuits and Systems

Abstract

Medical monitoring is undergoing a translation from the hospital-based system to the personalized home-based system. With the aim of wearable application of photoacoustic technique, we propose a miniaturized photoacoustic 3D imager for superficial medical imaging. By employing the compact continuous-wave laser diode based optical irradiation and an ultrathin 2D matrix array based photoacoustic detection in the coherent frequency domain, a wearable imaging probe with a size of about 80 × 25 × 24 mm3and a weight of 21 g is developed. At the backend, an FPGA controlled Howland current source drives the laser diodes to excite linear frequency modulated optical irradiation. Recorded by a portable multichannel data acquisition system, the generated photoacoustic responses are firstly compressed with the coherent frequency domain photoacoustic method and then extrapolated in the wavenumber-frequency domain for fast image reconstruction. With three-wavelength (450 nm, 638 nm, and 808 nm) laser irradiation, photoacoustic imaging can be operated multispectrally, endowing the developed imager with functional imaging capability in 3D space. With the imager worn on the human forearm, hemoglobin oxygen saturation level in superficial arm vasculature can be long-term monitored with high stability. When the imager is applied for imaging in a relatively large area (e.g., early melanoma detection in the human breast), flexible scanning in a handheld manner can be performed. This work opens the application potential of photoacoustic technique in a broad range of areas, including personalized healthcare, home health monitoring, and long-term physiologic monitoring.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2940243

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liu, S., Tang, K., Feng, X., Jin, H., Gao, F., & Zheng, Y.
Affiliations
  • Nanyang Technological University (SG)
  • Zhejiang University (CN)
  • ShanghaiTech University (CN)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2019-12
Volume
13
Issue
6
Pages
1417-1424
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2972832939
Cited by
25
References
27
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 6 · 2020: 2 · 2019: 1
FWCI
1.32
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
3D photoacoustic imaging, multispectral photoacoustic imaging, melanoma detection, home health monitoring, portable data acquisition
MeSH terms
Wearable Electronic Devices, Diagnostic Imaging, Equipment Design, Humans, Miniaturization, Phantoms, Imaging, Imaging, Three-Dimensional, Photoacoustic Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review