ECG Classification Algorithm Based on STDP and R-STDP Neural Networks for Real-Time Monitoring on Ultra Low-Power Personal Wearable Devices
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a novel ECG classification algorithm for inclusion as part of real-time cardiac monitoring systems in ultra low-power wearable devices. The proposed solution is based on spiking neural networks which are the third generation of neural networks. In specific, we employ spike-timing dependent plasticity (STDP), and reward-modulated STDP (R-STDP), in which the model weights are trained according to the timings of spike signals, and reward or punishment signals. Experiments show that the proposed solution is suitable for real-time operation, achieves comparable accuracy with respect to previous methods, and more importantly, its energy consumption in real-time classification of ECG signals is significantly smaller. In specific, energy consumption is 1.78 μJ per beat, which is 2 to 9 orders of magnitude smaller than previous neural network based ECG classification methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Neuronal Dynamics: From Single Neurons to Networks and Models of Cognition
Gerstner, W., Kistler, W. M., Naud, R., & Paninski, L. (2014) · doi:10.1017/cbo9781107447615 · Cited by 1,515 · cited 2×
“We employ one of the most popular models called Leaky Integrate-and-Fire (LIF) model [45] which operates based on the following equation.”
BackgroundMethodSopic, D., Aminifar, A., Aminifar, A., & Atienza, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2848477 · Cited by 97 · cited 2×
“Therefore, continuous ECG monitoring is crucial in early detection of potential problems [2].”
Background
Cited by
Application of artificial intelligence in wearable devices: Opportunities and challenges
Nahavandi, D., Alizadehsani, R., Khosravi, A., & Acharya, U. R. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106541 · Cited by 372
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., De Silva, L. C., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 353
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Shumba, A.-T., Montanaro, T., Sergi, I., Bramanti, A., Ciccarelli, M., Rispoli, A., Carrizzo, A., De Vittorio, M., & Patrono, L. (2023) · Sensors · doi:10.3390/s23156896 · Cited by 74
A Neural Network-Based ECG Classification Processor With Exploitation of Heartbeat Similarity
Wu, J., Li, F., Chen, Z., Pu, Y., & Zhan, M. (2019) · IEEE Access · doi:10.1109/access.2019.2956179 · Cited by 23
“An overall performance comparison between the proposed algorithm and other advanced patient-specific methods [7], [12], [13], [21] are shown in Table 3.”
BackgroundResult
Metadata
- Authors
- Amirshahi, A., & Hashemi, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2019-12
- Volume
- 13
- Issue
- 6
- Pages
- 1483-1493
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W3104801087
- Cited by
- 127
- References
- 3
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.