On the Transparency of the Stroma in the Mammalian Cornea
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper discusses the transparency of the normal mammalian cornea with particular reference to the scattering of light from the fibril structure in the stroma. It is shown theoretically that Maurice's fibril-lattice model would allow about 50Å rms isotropic fibril displacements from the ideal lattice positions to produce one percent scatter. This theoretically acceptable disorder seems to be in reasonable agreement with electron micrographic investigations. It is also shown that the scattered power is inversely proportional to the fifth power of the wavelength for this scattering model. Other scattering models are also discussed. These exhibit different wavelength dependence (1/λ3, 1/λ). Unfortunately no scatter versus wavelength measurements seem to have been reported in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129
Cited by
Corneal and scleral collagens—a microscopist’s perspective
Meek, K. M., & Fullwood, N. J. (2001) · Micron · doi:10.1016/s0968-4328(00)00041-x · Cited by 242
Transparency, swelling and scarring in the corneal stroma
Meek, K. M., Leonard, D. W., Connon, C. J., Dennis, S., & Khan, S. (2003) · Eye · doi:10.1038/sj.eye.6700574 · Cited by 230
Doutch, J., Quantock, A. J., Smith, V. A., & Meek, K. M. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.132316 · Cited by 65
Ultraviolet light transmission through the human corneal stroma is reduced in the periphery
Doutch, J. J., Quantock, A. J., Joyce, N. C., & Meek, K. M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.02.023 · Cited by 50
Kostyuk, O., Nalovina, O., Mubard, T. M., Regini, J. W., Meek, K. M., Quantock, A. J., Elliott, G. F., & Hodson, S. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.021527 · Cited by 41
Metadata
- Authors
- Feuk, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1970-07
- Volume
- BME-17
- Issue
- 3
- Pages
- 186-190
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1963702096
- Cited by
- 57
- References
- 1
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the Transparency of the Stroma in the Mammalian Cornea. https://app.cochat.ai/papers/10.1109/tbme.1970.4502732
- The paper
- Feuk, T. (1970). On the Transparency of the Stroma in the Mammalian Cornea. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1970.4502732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.