The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Development, Operation, and Application of the Ion-Sensitive Field-Effect Transistor as a Tool for Electrophysiology
Abstract
A new solid-state device has been developed for the measurement of ion activities in electrochemical and biological environments. One can recognize in the device the properties of both a glass electrode and a field-effect transistor. This justifies the name ion-sensitive field-effect transistor. The device makes it possible to measure ion activities without using a reference electrode. For its application, a special electronic circuit is described. Results of measured Na+and H+ion activities are given in detail. As an example for electrophysiological application, results are shown of recorded extracellular ion pulses measured with a guinea pig taenia coli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Self-citationCation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
Design theory of a surface field-effect transistor
Ihantola, H. K. J., & Moll, J. L. (1964) · Solid-State Electronics · doi:10.1016/0038-1101(64)90039-5 · Cited by 190
New Amplification Method for Depth Recording
Bergveld, P. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502544 · Cited by 15
Self-citationThe influence of substrate bias upon the AC characteristics of MOS transistors
Bergveld, P. (1969) · Proceedings of the IEEE · doi:10.1109/proc.1969.6871 · Cited by 5
Self-citation
Cited by
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Self-citationDiverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Organic field-effect transistor sensors: a tutorial review
Torsi, L., Magliulo, M., Manoli, K., & Palazzo, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60127g · Cited by 825
Patolsky, F., & Lieber, C. M. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00791-1 · Cited by 699
Bousse, L., De Rooij, N. F., & Bergveld, P. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21284 · Cited by 574
Self-citationRecent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Nanowire Sensors for Medicine and The Life Sciences
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nanomedicine · doi:10.2217/17435889.1.1.51 · Cited by 489
Conducting Polyaniline Nanowire and Its Applications in Chemiresistive Sensing
Song, E., & Choi, J.-W. (2013) · Nanomaterials · doi:10.3390/nano3030498 · Cited by 462
Electronic detection of DNA by its intrinsic molecular charge
Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., & Manalis, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232276699 · Cited by 443
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Matsuo, T., & Esashi, M. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80006-6 · Cited by 343
A generalized theory of an electrolyte-insulator-semiconductor field-effect transistor
Fung, C. D., Cheung, P. W., & Ko, W. H. (1986) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1986.22429 · Cited by 322
Micromechanical cantilever as an ultrasensitive pH microsensor
Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A. (2002) · Applied Physics Letters · doi:10.1063/1.1514825 · Cited by 300
Materials and techniques for electrochemical biosensor design and construction
Zhang, S. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00076-2 · Cited by 286
Gao, A., Lu, N., Dai, P., Li, T., Pei, H., Gao, X., Gong, Y., Wang, Y., & Fan, C. (2011) · Nano Letters · doi:10.1021/nl202303y · Cited by 285
p H response of GaN surfaces and its application for p H-sensitive field-effect transistors
Steinhoff, G., Hermann, M., Schaff, W. J., Eastman, L. F., Stutzmann, M., & Eickhoff, M. (2003) · Applied Physics Letters · doi:10.1063/1.1589188 · Cited by 284
Basic properties of the electrolyte—SiO2—Si system: Physical and theoretical aspects
Siu, W. M., & Cobbold, R. S. C. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19690 · Cited by 267
Lindner, E., & Umezawa, Y. (2008) · Pure and Applied Chemistry · doi:10.1351/pac200880010085 · Cited by 262
The role of buried OH sites in the response mechanism of inorganic-gate pH-sensitive ISFETs
Bousse, L., & Bergveld, P. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80028-1 · Cited by 198
Self-citationSensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Metadata
- Authors
- Bergveld, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1972-09
- Volume
- BME-19
- Issue
- 5
- Pages
- 342-351
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2072931302
- Cited by
- 654
- References
- 5
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.