Abstract
A miniaturized radio telemetry device has been developed which can monitor the magnitude and distribution of pressure generated between the cartilage-covered surface of the human hip socket and the surface of a hip prosthesis which replaces the spherical head of the femur in the hip. The pressure distribution is sensed by an array of 14 pressure transducers mounted inside the hollow ball of the prosthesis, and the signals from the transducers are transmitted to external receiving and recording equipment by a radio telemetry device also located inside the hollow ball.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
Self-citationValidation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Finite element prediction of cartilage contact stresses in normal human hips
Harris, M. D., Anderson, A. E., Henak, C. R., Ellis, B. J., Peters, C. L., & Weiss, J. A. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22040 · Cited by 212
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
“One early smart prosthetic hip used an array of 14 pressure transducers arranged inside the femoral head to characterize the distribution of forces within the joint during motion [88].”
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Metadata
- Authors
- Carlson, C. E., Mann, R. W., & Harris, W. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1974-07
- Volume
- BME-21
- Issue
- 4
- Pages
- 257-264
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2096401877
- Cited by
- 74
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Radio Telemetry Device for Monitoring Cartilage Surface Pressures in the Human Hip. https://app.cochat.ai/papers/10.1109/tbme.1974.324311
- The paper
- Carlson, C. E., Mann, R. W., & Harris, W. H. (1974). A Radio Telemetry Device for Monitoring Cartilage Surface Pressures in the Human Hip. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1974.324311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.