The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Electrochemical Considerations for Safe Electrical Stimulation of the Nervous System with Platinum Electrodes
Abstract
Electrical stimulation of the nervous system is of increasing importance for a variety of prospective neural prostheses. Electrochemical reactions which may occur at Pt or other noble metal-tissue interfaces are reviewed. Use of stimulus waveforms with a net direct current component increases the probability of tissue damage. There are three conceptually safe methods of injecting charge from a noble metal into tissue: modification of the electrical double layer at the interface and coupling via either of two symmetrical surface-layer oxidation-reduction processes. These reactions may be addressed with stimulus waveforms without a direct current component and with controlled charge densities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inhibition of Cell Division in Escherichia coli by Electrolysis Products from a Platinum Electrode
ROSENBERG, B., VAN CAMP, L., & KRIGAS, T. (1965) · Nature · doi:10.1038/205698a0 · Cited by 3,049
Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report.
Shealy, C. N., Mortimer, J. T., & RESWICK, J. B. (1990) · PubMed · Cited by 1,237
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Electrical Inhibition of Pain by Stimulation of the Dorsal Columns: Preliminary Clinical Report
SHEALY, C. N., MORTIMER, J. T., & RESWICK, J. B. (1967) · Anesthesia & Analgesia · doi:10.1213/00000539-196707000-00025 · Cited by 1,016
Temporary Abolition of Pain in Man
Wall, P. D., & Sweet, W. H. (1967) · Science · doi:10.1126/science.155.3758.108 · Cited by 969
Advances in electrochemistry and electrochemical engineering
Ibl, N. (1962) · Electrochimica Acta · doi:10.1016/0013-4686(62)80039-5 · Cited by 953
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS*
Schwan, H. P. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20349.x · Cited by 368
Electrical Stimulation of the Brain
MCCRUM, W. R. (1962) · American Journal of Psychiatry · doi:10.1176/ajp.119.4.389-a · Cited by 311
Brief, Noninjurious Electric Waveform for Stimulation of the Brain
Lilly, J. C., Hughes, J. R., Alvord, E. C., & Galkin, T. W. (1955) · Science · doi:10.1126/science.121.3144.468 · Cited by 287
electrical inhibition of pain: experimental evaluation*
SHEALY, C. N., TASLITZ, N., MORTIMER, J. T., & BECKER, D. P. (1967) · Anesthesia & Analgesia · doi:10.1213/00000539-196705000-00009 · Cited by 184
Brain tissue reaction to some chronically implanted metals
Dymond, A. M., Le, K., Jurist, J. M., & Crandall, P. H. (1970) · Journal of neurosurgery · doi:10.3171/jns.1970.33.5.0574 · Cited by 140
Biomaterials—The Interfacial Problem
Hench, L. L., & Ethridge, E. C. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-004905-9.50007-4 · Cited by 105
An analysis of electrical properties of metal electrodes
Weinman, J., & Mahler, J. (1964) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474626 · Cited by 104
The Production of Brain Lesions with Electric Currents
Rowland, V. C., MacIntyre, W. J., & Bidder, T. G. (1960) · Journal of neurosurgery · doi:10.3171/jns.1960.17.1.0055 · Cited by 98
Functional electrical stimulation for ambulation in hemiplegia.
MOE, J. H., & Hw, P. (1962) · PubMed · Cited by 85
Proportionally controlled functional electrical stimulation of hand.
Rebersek, S., & Vodovnik, L. (1973) · PubMed · Cited by 78
The erosion of electrodes by small currents
Loucks, R. B., Weinberg, H., & Smith, M. H. (1959) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(59)90132-4 · Cited by 58
AN ELECTROPHYSIOLOGIC SPLINT FOR THE HAND.
LONG, C. (1963) · PubMed · Cited by 51
Nonlinearity of Cardiac Pacemaker Electrodes
Jaron, D., Briller, S. A., Schwan, H. P., & Geselowitz, D. B. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502625 · Cited by 49
Electrochemical Corrosion of Platinum in Hydrochloric Acid Solutions
Llopis, J., & Sancho, A. (1961) · Journal of The Electrochemical Society · doi:10.1149/1.2428205 · Cited by 47
MYOCARDIAL AND ENDOCARDIAC ELECTRODES FOR CHRONIC IMPLANTATION
Greatbatch, W., & Chardack, W. M. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20352.x · Cited by 46
Wetzel, M. C., Howell, L. G., & Bearie, K. J. (1969) · Journal of neurosurgery · doi:10.3171/jns.1969.31.6.0658 · Cited by 36
Biphasic stimulation and electrical properties of metal electrodes
Weinman, J. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.4.787 · Cited by 36
Lilly, J. C., & Cherry, R. B. (1955) · Journal of Neurophysiology · doi:10.1152/jn.1955.18.1.18 · Cited by 36
Paraplegic Dogs: Urinary Bladder Evacuation with Direct Electric Stimulation
Kantrowitz, Á., & Schamaun, M. (1963) · Science · doi:10.1126/science.139.3550.115 · Cited by 22
Information processing in the central nervous system during functional electrical stimulation
Vodovnik, L. (1971) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474648 · Cited by 8
Experimental Brain Prosthesis for Stroke
Pinneo, L. R., Kaplan, J. N., Elpel, E. A., Reynolds, P. C., & Glick, J. H. (1972) · Stroke · doi:10.1161/01.str.3.1.16 · Cited by 8
Muscle Response to Internal Stimulation of the Peroneal Nerve in Paraplegic Patients
Yergler, W. G., & McNeal, D. R. (1971) · Springer eBooks · doi:10.1007/978-1-4684-8044-3_20 · Cited by 6
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Metadata
- Authors
- Brummer, S. B., & Turner, M. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1977-01
- Volume
- BME-24
- Issue
- 1
- Pages
- 59-63
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2067254323
- Cited by
- 359
- References
- 30
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.