Indirect Measurement of Instantaneous Arterial Blood Pressure in the Human Finger by the Vascular Unloading Technique
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For the indirect measurement of beat-to-beat systolic and diastolic pressure in the human finger, a new hydraulic servocontrol system was designed to maintain the vascular volume in the unloaded state. The servocontrol system consists of a compression chamber equipped with an occluding cuff and a photoelectric plethysmograph, an electromagnetic shaker, and a volume servo circuit. The shaker connected to a diaphragm actuator is used for controlling the cuff pressure. The vascular volume change in the finger is detected by the photoelectric plethysmograph. The plethysmographic signal is fed into the servo circuit to control the cuff pressure, which is clamped at a proper value corresponding to the unloaded vascular volume. At this state the controlled cuff pressure follows the intraarterial pressure. The accuracy of this method was evaluated using an in vitro vascular model of the finger. Comparisons with direct measurement were carried out successfully in four normotensive and six hypertensive subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287
Cited by
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Self-citationde Boer, R. W., Karemaker, J. M., & Strackee, J. (1985) · Medical and Biological Engineering and Computing · doi:10.1007/bf02441589 · Cited by 291
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“The volume-clamp method is an alternative PPG-based approach for measuring BP [160], [161].”
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442797 · Cited by 129
Self-citationCuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Metadata
- Authors
- Yamakoshi, K.-I., Shimazu, H., & Togawa, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1980-03
- Volume
- BME-27
- Issue
- 3
- Pages
- 150-155
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2039054481
- Cited by
- 139
- References
- 1
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).