Cited by 171Non-Invasive Vital Sign MonitoringCardiovascular Health and Disease PreventionHeart Rate Variability and Autonomic Control

The effect of contacting force on photoplethysmographic signals

Open access
Teng, X F, Zhang, Y T·2004·Physiological Measurement

Abstract

Photoplethysmography (PPG) has been used in oxygen saturation measurement, heart rate monitoring, and the assessment of peripheral circulation and large artery compliance. However, the waveform of the photoplethysmographic signal may be affected by the contacting force between the sensor and the measurement site. The aim of this study is to investigate the change in pulse amplitude (AC), DC amplitude, ratio of AC/DC and normalized pulse area of the reflective photoplethysmographic signals with increasing contacting force, from 0.2 N to 1.8 N. Signals were recorded from the fingers of fifteen healthy subjects. With increasing contacting force, the DC amplitude increased and the normalized pulse area decreased, whereas the pulse amplitude and the ratio of AC/DC increased first and then decreased. For different subjects, the pulse amplitude and the ratio of AC/DC peaked at different contacting forces, from 0.2 N to 1.0 N, and most of the subjects achieved their maximum pulse amplitude within 0.2-0.4 N. Over the range of contacting force between 0.2 N and 0.8 N, the DC amplitude and the normalized pulse area had significant changes (p < 0.001). The results suggest that the effects of contacting force should be carefully examined in the design of photoplethysmography-based health care devices.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/5/020

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • With an applied force at the finger of 0.2-1.8 N, there was an increase in AC amplitude and AC/DC ratio until the parameters reached a peak and then decreased, while the pulse area decreased, and the DC offset increased.

    “As reported by Teng and Zhang, with an applied force at the finger of 0.2–1.8 N, there was an increase in AC amplitude and AC/DC ratio until the parameters reached a peak and then decreased, while the pulse area decreased, and the DC offset increased [206].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 32 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Teng, X. F., & Zhang, Y. T.
Affiliations
Chinese University of Hong Kong (HK)
Venue
Physiological Measurement
Published
2004-08-12
Volume
25
Issue
5
Pages
1323-1335
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1965659123
Cited by
171
References
32
Citations by year
2026: 6 · 2025: 11 · 2024: 12 · 2023: 12 · 2022: 8 · 2021: 8 · 2020: 7 · 2019: 6 · 2018: 13 · 2017: 14 · 2016: 7 · 2015: 6 · 2014: 6 · 2013: 6 · 2012: 7
FWCI
5.94
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Funders
Innovation and Technology Fund
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, contact force, pulse amplitude, finger photoplethysmography
MeSH terms
Adult, Biomechanical Phenomena, Female, Humans, Male, Pressure, Pulse, Reproducibility of Results, Artifacts, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review