Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
A model of myelinated nerve axon was used to study the initiation and propagation of action potentials for a variety of extracellular electrical stimuli. Frankenhaeuser-Huxley nonlinearities were incorporated at each of several nodes in a longitudinal array, and the extracellular current pulse was modeled as a spatial distribution of voltage disturbance along the membrane. Results from the model were compared to data from human sensory experiments and from animal electrophysiological experiments. Effects of polarity, electrode position, pulse duration, and biphasic oscillation frequency were examined. Biphasic pulses have higher excitation thresholds than monophasic pulses, provided the duration of a single phase is short relative to the time constant of the membrane depolarization process. The shapes of strength/duration curves from sensory experiments conform well to model predictions for monophasic stimuli. Strength/frequency curves derived from the model are similar to those from sensory stimulation with sinusoidal currents. The shapes of strength/frequency curves can be explained by membrane integration effects at high frequencies and membrane leakage effects at low frequencies. The model predicts lower thresholds for cathodal than for anodal stimulation: the predicted degree of polarity selectivity is confirmed by direct stimulation of axons in animal experiments, but is at variance with the selectivity found in human transcutaneous stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191 · cited 1×
“In this model, membrane excitability is governed by the Hodgkin-Huxley equations [4].”
MethodWhich elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024 · cited 1×
“Ranck [22] discusses a qualitative model for stimulation near the terminus of a CNS neuron, and shows that anodal excitation can occur at lower stimulus levels than with 1005”
BackgroundNew Developments in Electromyography and Clinical Neurophysiology.
(1974) · Archives of Neurology · doi:10.1001/archneur.1974.00490320078016 · Cited by 1,622
Discharge Patterns of Single Fibers in the Cat's Auditory Nerve
Nelson, S. B., Watanabe, T., Thomas, E. C., & Louise, F. C. (1966) · Defense Technical Information Center (DTIC) · Cited by 1,531
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833 · cited 6×
“In previous work, McNeal [5] evaluated a cathodal point electrode placed one-half an internodal distance from the axon.”
BackgroundMethodResultInfluentialFrankenhaeuser, B., & Huxley, A. F. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007378 · Cited by 702 · cited 2×
“However, when the stimulus approaches the excitation threshold, membrane conductivity must be modelled by a set of nonlinear differential equations, such as those described by Frankenhaeuser and Huxley (FH equations) [6].”
MethodElectric Current Flow in Excitable Cells.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-916_1 · Cited by 528
Digital Computer Solutions for Excitation and Propagation of the Nerve Impulse
Cooley, J. W., & Dodge, F. A. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86679-1 · Cited by 267 · cited 1×
“One such model, developed by Cooley and Dodge [3], uses a lumped equivalent circuit to represent an unmyelinated fiber with stimulation by an intracellular electrode.”
MethodBostock, H. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014792 · Cited by 223
Computation of Impulse Initiation and Saltatory Conduction in a Myelinated Nerve Fiber
Fitzhugh, R. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86837-4 · Cited by 223 · cited 1×
“Myelinated fiber models studied by FitzHugh [7] and Bostock 18] make explicit assumptions about the role of the myelin internode, in addition to the active nonlinear properties at the nodes.”
Background
Cited by
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Pell, G. S., Roth, Y., & Zangen, A. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.003 · Cited by 406
Arena, C. B., Sano, M. B., Rossmeisl, J. H., Caldwell, J. L., Garcia, P. A., Rylander, M. N., & Davalos, R. V. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-102 · Cited by 361
Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293
Self-citationFrijns, J. H. M., de Snoo, S. L., & Schoonhoven, R. (1995) · Hearing Research · doi:10.1016/0378-5955(95)00090-q · Cited by 182
High-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
“This appears consistent with simulation results for neurons [28]”
BackgroundResult
Metadata
- Authors
- Reilly, J. P., Freeman, V. T., & Larkin, W. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1985-12
- Volume
- BME-32
- Issue
- 12
- Pages
- 1001-1011
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2049325685
- Cited by
- 195
- References
- 20
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.