Abstract

To test the hypothesis that only an adaptive algorithm would guarantee optimal feedback control of glycemia in insulin-dependent diabetes, fasting chronically diabetic dogs at rest were subjected to short-term artificial beta cell treatment. Insulin was applied intravenously and an oral glucose load was given during the experiment. Employing the same dosing algorithm, three different control strategies were employed in a random order on different days: adaptive control (minimum variance controller, Test A), fixed command control using on-line parameter estimates (Test B), and fixed command control using off-line individually optimized dosage constants (Test C). Comparison was made to nondiabetic control animals. The glycemic profiles were entirely normal in Test A and C, but were distinctly elevated in Test B. The peripheral hyperinsulinaemia could, however, not be avoided by adaptive control. It is concluded that the restoration of physiological blood glucose control in insulin-dependent diabetes requires dosage parameters which are either continually adapted to the actual situation (adaptive control) or are optimized to meet the individual's needs. In the latter case, fixed command control may be employed. Peripheral hyperinsulinaemia cannot be avoided as long as insulin is administered by a posthepatic route.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1987.326068

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 37

  1. fischer, 1985, the glucose-insulin metabolic control model: fields of application in insulin-dependent diabetes in addition to the artificial beta cell, Progr Artif Organs, 5, 662
  2. 10.1007/BF00290484 · DOI
  3. 10.1177/014233128300500406 · DOI
  4. 10.1109/TBME.1981.324661 · DOI · Paper page
  5. stephen, 1982, stabilization and improvement of renal function in diabetic nephropathy, Diabetic Nephropathy, 1, 8
  6. 10.2337/diacare.8.1.34 · doi:10.2337/diacare.8.1.34
  7. 10.2337/diab.34.2.S36 · DOI · Paper page
  8. 10.1007/BF00251284 · doi:10.1007/bf00251284
  9. 10.2337/diacare.4.2.265 · doi:10.2337/diacare.4.2.265
  10. bergeler, 1984, Biomedizinische Technik, 175, 10.1515/bmte.1984.29.s1.175 · doi:10.1515/bmte.1984.29.s1.175
  11. chisholm, 1984, a semi-closed loop computer-assisted insulin infusion system, Med J Australia, 22, 784, 10.5694/j.1326-5377.1984.tb132950.x · doi:10.5694/j.1326-5377.1984.tb132950.x
  12. 10.2337/diacare.4.2.311 · DOI · Paper page
  13. follinger, 1978, Regelungstechnik Einfaihrung in die Methoden und ihre Anwendung
  14. 10.1007/978-3-642-96341-4 · doi:10.1007/978-3-642-96341-4
  15. 10.1109/TBME.1983.325101 · doi:10.1109/tbme.1983.325101
  16. 10.1007/BF02584241 · doi:10.1007/bf02584241
  17. 10.1109/TBME.1985.325545 · doi:10.1109/tbme.1985.325545
  18. 10.1109/TBME.1985.325500 · DOI · Paper page
  19. 10.1055/s-2007-1019328 · DOI
  20. abel, 1984, experience with an implantable glucose sensor as a prerequisite of an artificial beta cell, Biomed Biochim Acta, 43, 577
  21. 10.1007/BF02442800 · DOI
  22. 10.1016/S0076-6879(85)12041-0 · doi:10.1016/s0076-6879(85)12041-0
  23. 10.1016/S0140-6736(82)92788-X · DOI · Paper page
  24. 10.2337/diacare.3.2.274 · DOI
  25. 10.2337/diacare.5.3.213 · doi:10.2337/diacare.5.3.213
  26. 10.1111/j.1525-1594.1985.tb04370.x · DOI
  27. 10.1109/TBME.1983.325203 · DOI · Paper page
  28. 10.1007/BF00250158 · DOI
  29. fischer, 1984, estimating artificial beta cell control parameters, Progr Artif Organs, 4, 794
  30. 10.1111/j.1525-1594.1985.tb04362.x · DOI
  31. salzsieder, 1984, estimation of individually adapted control parameters for an artificial beta cell, Biomed Biochim Acta, 43, 585
  32. tamborlane, 1984, insulin infusion pump treatment of type i diabetes, Pediatr Clin N Am, 31, 721, 10.1016/S0031-3955(16)34617-X · DOI
  33. freyse, 1982, low dose streptozotocin diabetes after partial pancreatectomy in dogs. histological findings in a new type of experimental diabetes, Acta Biol Med Germ, 41, 1203
  34. 10.1056/NEJM198207293070501 · DOI
  35. 10.2337/diabetes.30.12.1072 · doi:10.2337/diabetes.30.12.1072
  36. wheeler, 1984, computer graphics and parameter identification in diabetic therapy, Scand J Clin Lab Invest, 44, 390
  37. 10.1001/archinte.137.5.639 · doi:10.1001/archinte.137.5.639

Cited by

See all 66

Metadata

Authors
Fischer, U., Schenk, W., Salzsieder, E., Albrecht, G., Abel, P., & Freyse, E.-J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1987-08
Volume
BME-34
Issue
8
Pages
575-582
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1990549908
Cited by
66
References
0
FWCI
1.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does Physiological Blood Glucose Control Require an Adaptive Control Strategy? https://app.cochat.ai/papers/10.1109/tbme.1987.326068
The paper
Fischer, U., Schenk, W., Salzsieder, E., Albrecht, G., Abel, P., & Freyse, E.-J. (1987). Does Physiological Blood Glucose Control Require an Adaptive Control Strategy? IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1987.326068

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.