Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Over the past 15 years, several algorithms have been proposed and used for closed-loop blood glucose regulation. Their intent is to artificially replace the normal responses of the pancreatic beta cell absent in insulin-dependent diabetes. All of these algorithms calculate insulin infusion rates on the basis of minute-by-minute measurements of whole blood glucose concentration and its calculated rate of rise or fall. In addition, various techniques are employed to compensate for measurement delay time and the presence of noise in the measured signals. The goal of these feedback systems is to normalize blood glucose in diabetes mellitus. Interestingly, some recently "optimized" versions provide only a near normalization of glycemia in patients with insulin-dependent diabetes, a degree ofglycemic control which is not significantly different from intensified conventional insulin therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seltzer, H. S., Allen, E. W., Herron, A. L., & Brennan, M. T. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105534 · Cited by 883
Dynamics of Insulin Secretion by the Perfused Rat Pancreas
CURRY, D. L., BENNETT, L. L., & GRODSKY, G. M. (1968) · Endocrinology · doi:10.1210/endo-83-3-572 · Cited by 601
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Self-citationRizza, R. A., Gerich, J. E., Haymond, M. W., Westland, R. E., Hall, L. D., Clemens, A. H., & Service, F. J. (1980) · New England Journal of Medicine · doi:10.1056/nejm198012043032301 · Cited by 279
Research works printed but not linked: 24
- clemens, 1977, continuous blood glucose analysis and feedback control dynamics for glucose controlled insulin infusion (artificial beta-cell), Proc 14th Int Congr Therapeutics L'Extension Scientifique, 45
- clemens, 1977, the development of biostator, a glucose controlled insulin infusion system (gciis), Horm Metab Res Suppl, 7, 22
- clemens, 1979, feedback control dynamics for glucose controlled insulin infusion system, Med Progr Technol, 6, 91
- fischer, 1978, derivation and experimental proof of a new algorithm for the artificial bcell based on the individual analysis of the physiological insulinglucose relationship, Endokrinologie, 71, 65
- 10.1007/BF00290484 · DOI
- 10.2337/diab.28.6.558 · doi:10.2337/diab.28.6.558
- goriya, 1981, the metabolic and hormonal responses to a mixed meal in unrestrained pancreatectomised dogs chronically treated by portal or peripheral insulin infusion, Diabetolog, 19
- grodsky, 1967, Tolbutamide after Ten Years
- kadish, 1964, automatic control of blood sugar. i. a servomechanism for glucose monitoring and control, Amer J Med Electron, 3, 82
- 10.1007/BF01225463 · DOI
- 10.1111/j.0954-6820.1965.tb01810.x · DOI · Paper page
- 10.2337/diab.23.5.397 · DOI · Paper page
- 10.2337/diab.19.9.644 · DOI · Paper page
- 10.1007/BF02573823 · DOI
- 10.1109/TBME.1976.324639 · DOI
- 1976, Biostator (R) Glucose Controlled Insulin Infusion System Operating Manual
- botz, 1979, blood glucose regulation using closed-and open-loop insulin delivery systems. ii. peripheral primed square wave infusions, Diabetolg, 17, 45, 10.1007/BF01222977 · DOI
- 10.1109/PROC.1979.11448 · DOI
- 10.1530/acta.0.0870339 · DOI
- 10.1111/j.1445-5994.1977.tb03687.x · DOI · Paper page
- 10.1055/s-0028-1093650 · DOI · Paper page
- 10.2337/diabetes.26.7.663 · DOI
- 10.2337/diab.27.7.774 · doi:10.2337/diab.27.7.774
- 10.1055/s-0028-1093841 · DOI · Paper page
Cited by
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Metadata
- Authors
- Broekhuyse, H. M., Nelson, H. D., Zinman, B., & Albisser, A. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1981-10
- Volume
- BME-28
- Issue
- 10
- Pages
- 678-687
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1990162032
- Cited by
- 63
- References
- 4
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell. https://app.cochat.ai/papers/10.1109/tbme.1981.324661
- The paper
- Broekhuyse, H. M., Nelson, H. D., Zinman, B., & Albisser, A. M. (1981). Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1981.324661
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.