The DOI matches its Crossref record.
The conductivity of the human skull: results of in vivo and in vitro measurements
Abstract
The conductivity of the human skull was measured both in vitro and in vivo. The in vitro measurement was performed on a sample of fresh skull placed within a saline environment. For the in vivo measurement a small current was passed through the head by means of two electrodes placed on the scalp. The potential distribution thus generated on the scalp was measured in two subjects for two locations of the current injecting electrodes. Both methods revealed a skull conductivity of about 0.015 [symbol: see text]/m. For the conductivities of the brain, the skull and the scalp a ratio of 1:1/15:1 was found. This is consistent with some of the reports on conductivities found in the literature, but differs considerably from the ratio 1:1/80:1 commonly used in neural source localization. An explanation is provided for this discrepancy, indicating that the correct ratio is 1:1/15:1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multisensory integration: methodological approaches and emerging principles in the human brain.
Calvert, G. A., & Thesen, T. (2004) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.03.018 · Cited by 425
EEG source imaging enhances the decoding of complex right-hand motor imagery tasks
Edelman, B. J., Baxter, B., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467312 · Cited by 370
Spatiotemporal mapping of brain activity by integration of multiple imaging modalities
Dale, A. M., & Halgren, E. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00197-5 · Cited by 342
Interictal scalp fast oscillations as a marker of the seizure onset zone
Andrade-Valenca, L. P., Dubeau, F., Mari, F., Zelmann, R., & Gotman, J. (2011) · Neurology · doi:10.1212/wnl.0b013e318228bee2 · Cited by 285
The Virtual Brain Integrates Computational Modeling and Multimodal Neuroimaging
Ritter, P., Schirner, M., McIntosh, A. R., & Jirsa, V. K. (2013) · Brain Connectivity · doi:10.1089/brain.2012.0120 · Cited by 268
Effects of Forward Model Errors on EEG Source Localization
Akalin Acar, Z., & Makeig, S. (2013) · Brain Topography · doi:10.1007/s10548-012-0274-6 · Cited by 265
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
Milne, E., Scope, A., Pascalis, O., Buckley, D., & Makeig, S. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.07.017 · Cited by 148
High-resolution EEG techniques for brain-computer interface applications
Cincotti, F., Mattia, D., Aloise, F., Bufalari, S., Astolfi, L., De Vico Fallani, F., Tocci, A., Bianchi, L., Marciani, M. G., Gao, S., et al. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.06.031 · Cited by 115
fMRI–EEG integrated cortical source imaging by use of time-variant spatial constraints
Liu, Z., & He, B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.003 · Cited by 103
Lu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Dynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93
Sohrabpour, A., Lu, Y., Worrell, G., & He, B. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.05.064 · Cited by 89
“The conductivity of the three layers, i.e. brain, skull and skin, were selected respectively as 0.33 S/m, 0.0165 S/m and 0.33 S/m (Oostendorp et al, 2000; Lai et al., 2005; Zhang et al., 2006).”
MethodInfluentialSohrabpour, A., Ye, S., Worrell, G. A., Zhang, W., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616474 · Cited by 59
Dynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
Noninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22
Metadata
- Authors
- Oostendorp, T. F., Delbeke, J., & Stegeman, D. F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-11
- Volume
- 47
- Issue
- 11
- Pages
- 1487-1492
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2107348639
- Cited by
- 467
- References
- 0
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.