The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion
Abstract
This paper presents a novel approach for speckle reduction and coherence enhancement of ultrasound images based on nonlinear coherent diffusion (NCD) model. The proposed NCD model combines three different models. According to speckle extent and image anisotropy, the NCD model changes progressively from isotropic diffusion through anisotropic coherent diffusion to, finally, mean curvature motion. This structure maximally low-pass filters those parts of the image that correspond to fully developed speckle, while substantially preserving information associated with resolved-object structures. The proposed implementation algorithm utilizes an efficient discretization scheme that allows for real-time implementation on commercial systems. The theory and implementation of the new technique are presented and verified using phantom and clinical ultrasound images. In addition, the results from previous techniques are compared with the new method to demonstrate its performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wavelet transform domain filters: a spatially selective noise filtration technique
Xu, Y., Weaver, J. B., Healy, D. M., & Lu, J. (1994) · IEEE Transactions on Image Processing · doi:10.1109/83.336245 · Cited by 747
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Oriented Speckle Reducing Anisotropic Diffusion
Krissian, K., Westin, C.-F., Kikinis, R., & Vosburgh, K. G. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.891803 · Cited by 377
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323
Automatic breast ultrasound image segmentation: a survey
Xian, M., Zhang, Y., Cheng, H. D., Xu, F., Zhang, B., & Ding, J. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2018.02.012 · Cited by 284
Metadata
- Authors
- Abd-Elmoniem, K. Z., Youssef, A.-B. M., & Kadah, Y. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002-09
- Volume
- 49
- Issue
- 9
- Pages
- 997-1014
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2068075086
- Cited by
- 403
- References
- 1
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.