Prediction of Myelinated Nerve Fiber Stimulation Thresholds: Limitations of Linear Models
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Computer models of neurons are used to simulate neural behavior, and are important tools for designing neural prostheses. Computation time remains an issue when simulating large numbers of neurons or applying models to real time applications. Warman et al. developed a method to predict excitation thresholds for axons using linear models and a predetermined critical voltage. We calculated threshold prediction error as a function of the location of an extracellular electrode using two different axon models to examine further threshold prediction using linear models. Threshold prediction error was low (<3% error) under the conditions examined by Warman et al., but under more general conditions, threshold prediction error was as high as 23.6%. Linear models were limited as effective tools for single fiber threshold prediction because accuracy was dependent on the nonlinear and linear models used, and any parameter that affected the extracellular potential distribution. Threshold prediction could be improved by appropriately choosing the membrane conductance of the linear model, but determination of an optimal conductance was computationally expensive. Finally, although single fiber threshold prediction error was partially masked when considering the input-output (I/O) properties of populations of axons, relatively large errors still occurred in population I/O curves generated with linear models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681 · cited 1×
“Less computationally intensive approaches for characterizing the response of neurons to extracellular stimulation include using the activating function concept to predict regions of depolarization [15], using linear models and a preselected threshold voltage to determine excitation [16], [17], and using a hybrid model…”
MethodA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196 · cited 1×
“Less computationally intensive approaches for characterizing the response of neurons to extracellular stimulation include using the activating function concept to predict regions of depolarization [15], using linear models and a preselected threshold voltage to determine excitation [16], [17], and using a hybrid model…”
MethodRattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121 · cited 2×
“was employed subsequently in studies on the region of a peripheral nerve trunk activated by a cuff electrode [20], the electric field effects on a single fiber [21], and nerve cuff electrode selectivity [5].”
MethodInversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
Self-citation
Cited by
Faisal, A. A., Selen, L. P. J., & Wolpert, D. M. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2258 · Cited by 2,883
McIntyre, C. C., Mori, S., Sherman, D. L., Thakor, N. V., & Vitek, J. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.033 · Cited by 492
Self-citationRole of electrode design on the volume of tissue activated during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/001 · Cited by 309
Self-citationCurrent steering to control the volume of tissue activated during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2008) · Brain Stimulation · doi:10.1016/j.brs.2007.08.004 · Cited by 236
“However, ΔVe/Δx has limitations as a direct predictor of action potential threshold [28–30], and when multiple current sources are active simultaneously, simple relationships between ΔVe/Δx and axonal threshold break down.”
BackgroundSelf-citationSpatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Metadata
- Authors
- Moffitt, M. A., McIntyre, C. C., & Grill, W. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-02
- Volume
- 51
- Issue
- 2
- Pages
- 229-236
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2150494770
- Cited by
- 64
- References
- 6
- FWCI
- 0.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.