Using Wavelet Transform and Fuzzy Neural Network for VPC Detection From the Holter ECG
Abstract
A novel method for detecting ventricular premature contraction (VPC) from the Holter system is proposed using wavelet transform (WT) and fuzzy neural network (FNN). The basic ideal and major advantage of this method is to reuse information that is used during QRS detection, a necessary step for most ECG classification algorithm, for VPC detection. To reduce the influence of different artifacts, the filter bank property of quadratic spline WT is explored. The QRS duration in scale three and the area under the QRS complex in scale four are selected as the characteristic features. It is found that the R wave amplitude has a marked influence on the computation of proposed characteristic features. Thus, it is necessary to normalize these features. This normalization process can reduce the effect of alternating R wave amplitude and achieve reliable VPC detection. After normalization and excluding the left bundle branch block beats, the accuracies for VPC classification using FNN is 99.79%. Features that are extracted using quadratic spline wavelet were used successfully by previous investigators for QRS detection. In this study, using the same wavelet, it is demonstrated that the proposed feature extraction method from different WT scales can effectively eliminate the influence of high and low-frequency noise and achieve reliable VPC classification. The two primary advantages of using same wavelet for QRS detection and VPC classification are less computation and less complexity during actual implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
Melgani, F., & Bazi, Y. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.923147 · Cited by 525
A Generic and Robust System for Automated Patient-Specific Classification of ECG Signals
Ince, T., Kiranyaz, S., & Gabbouj, M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013934 · Cited by 481
LSTM-Based ECG Classification for Continuous Monitoring on Personal Wearable Devices
Saadatnejad, S., Oveisi, M., & Hashemi, M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2911367 · Cited by 406
Inan, O. T., Giovangrandi, L., & Kovacs, G. T. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880879 · Cited by 402
Metadata
- Authors
- Shyu, L.-Y., Wu, Y.-H., & Hu, W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-07
- Volume
- 51
- Issue
- 7
- Pages
- 1269-1273
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2104330778
- Cited by
- 236
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Wavelet Transform and Fuzzy Neural Network for VPC Detection From the Holter ECG. https://app.cochat.ai/papers/10.1109/tbme.2004.824131
- The paper
- Shyu, L.-Y., Wu, Y.-H., & Hu, W. (2004). Using Wavelet Transform and Fuzzy Neural Network for VPC Detection From the Holter ECG. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.824131
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.