Classification of Single-Trial Electroencephalogram During Finger Movement
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We present an algorithm to discriminate between the single-trial electroencephalograms (EEG) of two different finger movement tasks. The method uses a spatio-temporal analysis to classify the EEG recorded during voluntary left versus right finger movement tasks. This algorithm produced a classification accuracy of 92.1% on the data from five subjects, without requiring subject training or data selection. This technique can be employed in an EEG-based brain-computer interface due to its high recognition rate, insensitivity to noise, and simplicity in computation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“The unique features of rapid response and relatively inexpensive implementation have made the electroencephalogram (EEG) a practical tool for establishing nonmuscular communication and control channels [1].”
BackgroundMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Designing optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
BCI meeting 2005-workshop on BCI signal processing: feature extraction and translation
McFarland, D. J., Anderson, C. W., Muller, K.-R., Schlogl, A., & Krusienski, D. J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875637 · Cited by 204
“Feature extraction 1) Time a) Fourier transform [1]–[7] b) Wavelets [8] c) Autoregressive models [2], [9]–[12] d) Bandpass filtering [13] e) Template matching [14] f) Kalman filter [11], [12], [14] g) Spike detection [15] 2) Space a) Laplacian filter [3], [9], [10], [16]–[18] b) Principal components analysis [8], [14]…”
MethodInfluentialJeon, Y., Nam, C. S., Kim, Y.-J., & Whang, M. C. (2011) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2011.03.005 · Cited by 193
Decoding Individual Finger Movements from One Hand Using Human EEG Signals
Liao, K., Xiao, R., Gonzalez, J., & Ding, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085192 · Cited by 174
Jochumsen, M., Niazi, I. K., Mrachacz-Kersting, N., Farina, D., & Dremstrup, K. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056015 · Cited by 128
“and desynchronization with the Bereitschaftspotential for discrimination between left and right finger movements [29].”
Background
Metadata
- Authors
- Li, Y., Gao, X., Liu, H., & Gao, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-06
- Volume
- 51
- Issue
- 6
- Pages
- 1019-1025
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2119834947
- Cited by
- 79
- References
- 4
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.