The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Asymptotic SNR of Scalar and Vector Minimum-Variance Beamformers for Neuromagnetic Source Reconstruction
Open accessAbstract
To reconstruct neuromagnetic sources, the minimum-variance beamformer has been extended to incorporate the three-dimensional vector nature of the sources, and two types of extensions-the scalar- and vector-type extensions-have been proposed. This paper discusses the asymptotic signal-to-noise ratio (SNR) of the outputs of these two types of beamformers. We first show that these two types of beamformers give exactly the same output power and output SNR if the beamformer pointing direction is optimized. We then compare the output SNR of the beamformer with optimum direction to that of the conventional vector beamformer formulation where the beamformer pointing direction is not optimized. The comparison shows that the beamformer with optimum direction gives an output SNR superior to that of the conventional vector beamformer. Numerical examples validating the results of the analysis are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix Analysis and Applied Linear Algebra
Meyer, C. (2000) · doi:10.1137/1.9780898719512 · Cited by 3,565
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Cited by
Hillebrand, A., Barnes, G. R., Bosboom, J. L., Berendse, H. W., & Stam, C. J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.005 · Cited by 416
Self-paced movements induce high-frequency gamma oscillations in primary motor cortex
Cheyne, D., Bells, S., Ferrari, P., Gaetz, W., & Bostan, A. C. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.178 · Cited by 325
Cheyne, D., Bakhtazad, L., & Gaetz, W. (2006) · Human Brain Mapping · doi:10.1002/hbm.20178 · Cited by 298
Roux, F., Wibral, M., Singer, W., Aru, J., & Uhlhaas, P. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.5778-12.2013 · Cited by 169
Can EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Fellrath, J., Mottaz, A., Schnider, A., Guggisberg, A. G., & Ptak, R. (2016) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2016.07.012 · Cited by 77
Automated localization of magnetoencephalographic interictal spikes by adaptive spatial filtering
Kirsch, H. E., Robinson, S. E., Mantle, M., & Nagarajan, S. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.06.708 · Cited by 66
Self-citationAdaptive reorganization of cortical networks in Alzheimer’s disease
Dubovik, S., Bouzerda-Wahlen, A., Nahum, L., Gold, G., Schnider, A., & Guggisberg, A. G. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.05.028 · Cited by 34
Neural correlates of fatigue after traumatic brain injury
Anliker, A. E., Chauvigné, L. A. S., Allaman, L., & Guggisberg, A. G. (2025) · Brain Communications · doi:10.1093/braincomms/fcaf082 · Cited by 1
Metadata
- Authors
- Sekihara, K., Nagarajan, S. S., Poeppel, D., & Marantz, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-10
- Volume
- 51
- Issue
- 10
- Pages
- 1726-1734
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159338671
- Cited by
- 193
- References
- 2
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.