Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Motion Estimation in Beating Heart Surgery

Ortmaier, T., Groger, M., Boehm, D.H., Falk, V., Hirzinger, G.·2005·IEEE Transactions on Biomedical Engineering

Abstract

Minimally invasive beating-heart surgery offers substantial benefits for the patient, compared to conventional open surgery. Nevertheless, the motion of the heart poses increased requirements to the surgeon. To support the surgeon, algorithms for an advanced robotic surgery system are proposed, which offer motion compensation of the beating heart. This implies the measurement of heart motion, which can be achieved by tracking natural landmarks. In most cases, the investigated affine tracking scheme can be reduced to an efficient block matching algorithm allowing for realtime tracking of multiple landmarks. Fourier analysis of the motion parameters shows two dominant peaks, which correspond to the heart and respiration rates of the patient. The robustness in case of disturbance or occlusion can be improved by specially developed prediction schemes. Local prediction is well suited for the detection of single tracking outliers. A global prediction scheme takes several landmarks into account simultaneously and is able to bridge longer disturbances. As the heart motion is strongly correlated with the patient's electrocardiogram and respiration pressure signal, this information is included in a novel robust multisensor prediction scheme. Prediction results are compared to those of an artificial neural network and of a linear prediction approach, which shows the superior performance of the proposed algorithms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2005.855716

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 31

  1. Falk, 1999, Endoscopic coronary artery bypass grafting on the beating heart using a computer enhanced telemanipulation system, Heart Surg. Forum, 2, 199
  2. Kodera, 2001, Closed chest CABG on the beating heart with a computer-enhanced articulating system: Case report, Heart Surg. Forum, 4, 305
  3. Sackier, 1995, Computer-Integrated Surgery, 577
  4. 10.1109/robot.2000.844121 · DOI · Paper page
  5. 10.1016/S0003-4975(00)02003-8 · doi:10.1016/s0003-4975(00)02003-8
  6. 10.1055/s-2002-34585 · doi:10.1055/s-2002-34585
  7. 10.1055/s-2000-6902 · doi:10.1055/s-2000-6902
  8. Koransky, 2003, Quantification of mechanical stabilization for the performance of off-pump coronary artery surgery, Heart Surg. Forum, 6, 224
  9. 10.1016/S0003-4975(02)03734-7 · doi:10.1016/s0003-4975(02)03734-7
  10. 10.1016/1062-1458(96)86754-7 · doi:10.1016/1062-1458(96)86754-7
  11. Koransky, 2001, Quantification of mechanical stabilization for the performance of off-pump coronary artery surgery, Heart Surg. Forum, 4, 125
  12. Salvendy, 1987, Wiley, 182
  13. 10.1016/S0003-4975(02)03457-4 · DOI
  14. 10.1016/S0003-4975(03)01058-0 · DOI
  15. 10.1016/S1474-6670(17)37999-5 · doi:10.1016/s1474-6670(17)37999-5
  16. 10.1109/IROS.2000.894664 · doi:10.1109/iros.2000.894664
  17. Preusche, 2002, Teleoperation concepts in minimally invasive surgery, Contr. Eng. Practice J., 10
  18. 10.1109/ROBOT.2001.932903 · doi:10.1109/robot.2001.932903
  19. 10.1109/ROBOT.2004.1307163 · doi:10.1109/robot.2004.1307163
  20. Stöffler, 2001, Realzeitfähige Bestimmung und Interpretation des optischen Flusses zur Navigation mit einem mobilen Roboter
  21. 10.1007/BFb0015547 · DOI
  22. 10.1109/ICCV.1995.466872 · DOI
  23. 10.1109/TMI.2003.809090 · doi:10.1109/tmi.2003.809090
  24. 10.1109/42.310876 · doi:10.1109/42.310876
  25. 10.1117/12.466926 · doi:10.1117/12.466926
  26. 10.1007/3-540-45404-7_8 · doi:10.1007/3-540-45404-7_8
  27. Weigend, 1993, Time Series Prediction. Forecasting the Future and Understanding the Past
  28. Kantz, 1997, Nonlinear Time Series Analysis
  29. Ortmaier, Robust motion estimation in robotic surgery on the beating heart, 206
  30. Wei, 1997, Real-time visual servoing for laparoscopic surgery, IEEE Eng. Med. Biol. Mag., 16, 40, 10.1109/51.566151 · DOI
  31. 10.1002/acs.4480080502 · doi:10.1002/acs.4480080502

Cited by

See all 187

Metadata

Authors
Ortmaier, T., Groger, M., Boehm, D. H., Falk, V., & Hirzinger, G.
Venue
IEEE Transactions on Biomedical Engineering
Published
2005-10
Volume
52
Issue
10
Pages
1729-1740
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2130643598
Cited by
187
References
1
FWCI
14.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion Estimation in Beating Heart Surgery. https://app.cochat.ai/papers/10.1109/tbme.2005.855716
The paper
Ortmaier, T., Groger, M., Boehm, D. H., Falk, V., & Hirzinger, G. (2005). Motion Estimation in Beating Heart Surgery. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.855716

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.