The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Real-Time EMG Pattern Recognition System Based on Linear-Nonlinear Feature Projection for a Multifunction Myoelectric Hand
Abstract
This paper proposes a novel real-time electromyogram (EMG) pattern recognition for the control of a multifunction myoelectric hand from four channel EMG signals. To extract a feature vector from the EMG signal, we use a wavelet packet transform that is a generalized version of wavelet transform. For dimensionality reduction and nonlinear mapping of the features, we also propose a linear-nonlinear feature projection composed of principal components analysis (PCA) and a self-organizing feature map (SOFM). The dimensionality reduction by PCA simplifies the structure of the classifier and reduces processing time for the pattern recognition. The nonlinear mapping by SOFM transforms the PCA-reduced features into a new feature space with high class separability. Finally, a multilayer perceptron (MLP) is used as the classifier. Using an analysis of class separability by feature projections, we show that the recognition accuracy depends more on the class separability of the projected features than on the MLP's class separation ability. Consequently, the proposed linear-nonlinear projection method improves class separability and recognition accuracy. We implement a real-time control system for a multifunction virtual hand. Our experimental results show that all processes, including virtual hand control, are completed within 125 ms, and the proposed method is applicable to real-time myoelectric hand control without an operational time delay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Cited by
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Metadata
- Authors
- Chu, J.-U., Moon, I., & Mun, M.-S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-11
- Volume
- 53
- Issue
- 11
- Pages
- 2232-2239
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2092102206
- Cited by
- 352
- References
- 1
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Real-Time EMG Pattern Recognition System Based on Linear-Nonlinear Feature Projection for a Multifunction Myoelectric Hand. https://app.cochat.ai/papers/10.1109/tbme.2006.883695
- The paper
- Chu, J.-U., Moon, I., & Mun, M.-S. (2006). A Real-Time EMG Pattern Recognition System Based on Linear-Nonlinear Feature Projection for a Multifunction Myoelectric Hand. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.883695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.