Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A noninvasive and unconstrained real-time method to detect the respiration rhythm and pulse rate during sleep is presented. By employing the a trous algorithm of the wavelet transformation (WT), the respiration rhythm and pulse rate can be monitored in real-time from a pressure signal acquired with a pressure sensor placed under a pillow. The waveform for respiration rhythm detection is derived from the 26 scale approximation, while that for pulse rate detection is synthesized by combining the 2(4) and 2(5) scale details. To minimize the latency in data processing and realize the highest real-time performance, the respiration rhythm and pulse rate are estimated by using waveforms directly derived from the WT approximation and detail components without the reconstruction procedure. This method is evaluated with data collected from 13 healthy subjects. By comparing with detections from finger photoelectric plethysmograms used for pulse rate detection, the sensitivity and positive predictivity were 99.17% and 98.53%, respectively. Similarly, for respiration rhythm, compared with detections from nasal thermistor signals, results were 95.63% and 95.42%, respectively. This study suggests that the proposed method is promising to be used in a respiration rhythm and pulse rate monitor for real-time monitoring of sleep-related diseases during sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“The algorithm for detecting the pulse rate from either the FPP or the estimated pulse-related waveform is an adaptive pulse peak pursuit method refined from the ECG R-wave detection algorithm in Pan et al. [28].”
MethodFast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246 · cited 2×
“This phenomenon leads to dissatisfaction with the instant mixing requirement in the linear ICA model [29] and, therefore, to incomplete separation of the pulse and respiration waveforms [15].”
BackgroundMethodCharacterization of signals from multiscale edges
Mallat, S., & Zhong, S. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.142909 · Cited by 3,200
The discrete wavelet transform: wedding the a trous and Mallat algorithms
Shensa, M. J. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.157290 · Cited by 1,994 · cited 4×
“Moreover, the avoidance of subsampling procedure by using the a trous algorithm [ 24 ] also assures phase shift invariance, which means that the algorithm can be easily implemented using any digital signal processor in real world applications.”
MethodInfluentialA Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605 · cited 2×
“The algorithm for detecting the pulse rate from either the FPP or the estimated pulse-related waveform is an adaptive pulse peak pursuit method refined from the ECG R-wave detection algorithm in Pan et al. [28].”
MethodDetection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
de Chazal, P., Heneghan, C., Sheridan, E., Reilly, R., Nolan, P., & O'Malley, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812203 · Cited by 433
Wavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415 · cited 1×
“WT multiresolution analysis can be applied to detect ECG characteristic points [18], to perform data compression [19], to extract the fetal ECG [20], and to delineate ECG [21].”
MethodTime Frequency and Wavelets in Biomedical Signal Processing
Akay, M. (1997) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546697 · Cited by 386
An Electrocardiogram-Based Technique to Assess Cardiopulmonary Coupling During Sleep
Thomas, R. J., Mietus, J. E., Peng, C.-K., & Goldberger, A. L. (2005) · Sleep · doi:10.1093/sleep/28.9.1151 · Cited by 335 · cited 1×
“884641 treatment of disorders like sleep apnea, sudden death syndrome [2], and heart diseases [3]–[5].”
Background
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“Additional methods for heartbeat detection from BCG signals include those which combine different estimators [46], [66], [67], and methods which use wavelets to preprocess the signal prior to peak detection [53], [68].”
BackgroundMethodSmart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“filled tubing [31], [32] have been used for monitoring in bed.”
MethodWireless Capacitive-Based ECG Sensing for Feature Extraction and Mobile Health Monitoring
Wannenburg, J., Malekian, R., & Hancke, G. P. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2844122 · Cited by 66
Metadata
- Authors
- Zhu, X., Chen, W., Nemoto, T., Kanemitsu, Y., Kitamura, K., Yamakoshi, K., & Wei, D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-12
- Volume
- 53
- Issue
- 12
- Pages
- 2553-2563
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2107203001
- Cited by
- 171
- References
- 21
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep. https://app.cochat.ai/papers/10.1109/tbme.2006.884641
- The paper
- Zhu, X., Chen, W., Nemoto, T., Kanemitsu, Y., Kitamura, K., Yamakoshi, K., & Wei, D. (2006). Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.884641
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.