The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A Model-Based Deconvolution Approach to Solve Fiber Crossing in Diffusion-Weighted MR Imaging
Abstract
A deconvolution approach is presented to solve fiber crossing in diffusion magnetic resonance imaging. In order to provide a direct physical interpretation of the signal generation process, we started from the classical multicompartment model and rewrote this in terms of a convolution process, identifying a significant scalar parameter alpha to characterize the physical system response. Deconvolution is performed by a modified version of the Richardson-Lucy algorithm. Simulations show the ability of this method to correctly separate fiber crossing, even in the presence of noisy data, with lower signal-to-noise ratio, and imprecision in the impulse response function imposed during deconvolution. The in vivo data confirms the efficacy of this method to resolve fiber crossing in real complex brain structures. These results suggest the usefulness of our approach in fiber tracking or connectivity studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866 · cited 1×
“Therefore, we propose a robust deconvolution algorithm based on a modified version of the classical Richardson-Lucy algorithm [21], [22].”
MethodDiffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 5×
“This is not true in the case of complex and heterogeneous structures where the presence of multiple fibers (crossing, diverging, or converging) cannot be described correctly by a single tensor but requires multicompartmental modeling [7], [8].”
BackgroundMethodInfluential
Cited by
MRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
Thomas, C., Ye, F. Q., Irfanoglu, M. O., Modi, P., Saleem, K. S., Leopold, D. A., & Pierpaoli, C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405672111 · Cited by 725
Thiebaut de Schotten, M., ffytche, D. H., Bizzi, A., Dell'Acqua, F., Allin, M., Walshe, M., Murray, R., Williams, S. C., Murphy, D. G. M., & Catani, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.055 · Cited by 656
Self-citationDeterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698
Monkey to human comparative anatomy of the frontal lobe association tracts
Thiebaut de Schotten, M., Dell’Acqua, F., Valabregue, R., & Catani, M. (2012) · Cortex · doi:10.1016/j.cortex.2011.10.001 · Cited by 632
Self-citationAccelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Jbabdi, S., Sotiropoulos, S. N., Savio, A. M., Graña, M., & Behrens, T. E. J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24204 · Cited by 399
Tournier, J. ‐., Calamante, F., & Connelly, A. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3017 · Cited by 403
Building connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290
White, N. S., Leergaard, T. B., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2013) · Human Brain Mapping · doi:10.1002/hbm.21454 · Cited by 273
Beyond cortical localization in clinico-anatomical correlation
Catani, M., Dell'Acqua, F., Bizzi, A., Forkel, S. J., Williams, S. C., Simmons, A., Murphy, D. G., & Thiebaut de Schotten, M. (2012) · Cortex · doi:10.1016/j.cortex.2012.07.001 · Cited by 263
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
Ball and rackets: inferring fiber fanning from diffusion-weighted MRI
Sotiropoulos, S. N., Behrens, T. E. J., & Jbabdi, S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.056 · Cited by 156
Sotiropoulos, S. N., Hernández-Fernández, M., Vu, A. T., Andersson, J. L., Moeller, S., Yacoub, E., Lenglet, C., Ugurbil, K., Behrens, T. E. J., & Jbabdi, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.014 · Cited by 110
AxTract: Toward microstructure informed tractography
Girard, G., Daducci, A., Petit, L., Thiran, J., Whittingstall, K., Deriche, R., Wassermann, D., & Descoteaux, M. (2017) · Human Brain Mapping · doi:10.1002/hbm.23741 · Cited by 62
Metadata
- Authors
- Dell'Acqua, F., Rizzo, G., Scifo, P., Clarke, R. A., Scotti, G., & Fazio, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-03
- Volume
- 54
- Issue
- 3
- Pages
- 462-472
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2138836107
- Cited by
- 194
- References
- 7
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.