The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tapered Conical Polymer Microneedles Fabricated Using an Integrated Lens Technique for Transdermal Drug Delivery
Abstract
Administration of protein and DNA biotherapeutics is limited by the need for hypodermic injection. Use of micron-scale needles to deliver drugs in a minimally invasive manner provides an attractive alternative, but application of this approach is limited by the need for suitable microneedle designs and fabrication methods. To address this need, this paper presents a conical polymer microneedle design that is fabricated using a novel integrated lens technique and analyzed for its ability to insert into the skin without mechanical failure. Microneedle master structures were fabricated using microlenses etched into a glass substrate that focused light through SU-8 negative epoxy resist to produce sharply tapered structures. Microneedle replicates were fabricated out of biodegradable polymers by micromolding. Because microneedle mechanical properties are critical to their insertion into the skin, we theoretically modeled two failure modes (axial mode and transverse mode), and analytical models were compared with measured data showing general agreement. Guided by this analysis, polymer microneedles were designed and demonstrated to insert to different depths into porcine skin in vitro. "Long" polymer microneedles were also demonstrated in human subjects to insert deeply without failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationAldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Xiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23
Metadata
- Authors
- Park, J.-H., Yoon, Y.-K., Choi, S.-O., Prausnitz, M. R., & Allen, M. G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-05
- Volume
- 54
- Issue
- 5
- Pages
- 903-913
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2129771529
- Cited by
- 172
- References
- 1
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tapered Conical Polymer Microneedles Fabricated Using an Integrated Lens Technique for Transdermal Drug Delivery. https://app.cochat.ai/papers/10.1109/tbme.2006.889173
- The paper
- Park, J.-H., Yoon, Y.-K., Choi, S.-O., Prausnitz, M. R., & Allen, M. G. (2007). Tapered Conical Polymer Microneedles Fabricated Using an Integrated Lens Technique for Transdermal Drug Delivery. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.889173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.