The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Abstract
This paper presents the design and testing of a portable magnetic system combined with miniature inertial sensors for ambulatory 6 degrees of freedom (DOF) human motion tracking. The magnetic system consists of three orthogonal coils, the source, fixed to the body and 3-D magnetic sensors, fixed to remote body segments, which measure the fields generated by the source. Based on the measured signals, a processor calculates the relative positions and orientations between source and sensor. Magnetic actuation requires a substantial amount of energy which limits the update rate with a set of batteries. Moreover, the magnetic field can easily be disturbed by ferromagnetic materials or other sources. Inertial sensors can be sampled at high rates, require only little energy and do not suffer from magnetic interferences. However, accelerometers and gyroscopes can only measure changes in position and orientation and suffer from integration drift. By combing measurements from both systems in a complementary Kalman filter structure, an optimal solution for position and orientation estimates is obtained. The magnetic system provides 6 DOF measurements at a relatively low update rate while the inertial sensors track the changes position and orientation in between the magnetic updates. The implemented system is tested against a lab-bound camera tracking system for several functional body movements. The accuracy was about 5 mm for position and 3 degrees for orientation measurements. Errors were higher during movements with high velocities due to relative movement between source and sensor within one cycle of magnetic actuation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
introduction to random signals and applied kalman filtering
Brown, R. G., & Hwang, P. Y. (1992) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,365
Kuipers, J. B. (1999) · Princeton University Press eBooks · doi:10.1515/9780691211701 · Cited by 1,290
Gustafsson, F., & Gunnarsson, F. (2005) · IEEE Signal Processing Magazine · doi:10.1109/msp.2005.1458284 · Cited by 996
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Quaternions and Rotation Sequences
Kuipers, J. (2020) · Princeton University Press eBooks · doi:10.2307/j.ctvx5wc3k · Cited by 637
Magnetic Position and Orientation Tracking System
Raab, F., Blood, E., Steiner, T., & Jones, H. (1979) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1979.308860 · Cited by 614
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Self-citationA New Mathematical Formulation for Strapdown Inertial Navigation
Bortz, J. (1971) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1971.310252 · Cited by 416
A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package
Zhu, R., & Zhou, Z. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827825 · Cited by 390
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“RECENT developments in miniature sensor technology have opened many possibilities for motion analysis outside the laboratory [3].”
BackgroundInertial head-tracker sensor fusion by a complementary separate-bias Kalman filter
Foxlin, E. (1996) · Proceedings of the IEEE 1996 Virtual Reality Annual International Symposium · doi:10.1109/vrais.1996.490527 · Cited by 365
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Self-citationEbaugh, D. D., McClure, P. W., & Karduna, A. R. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.06.015 · Cited by 235
Ambulatory measurement of ground reaction forces
Veltink, P. H., Liedtke, C., Droog, E., & van der Kooij, H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847359 · Cited by 161
Self-citationGiansanti, D., Maccioni, G., & Macellari, V. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847404 · Cited by 142
Bachmann, E. R. (2000) · Cited by 140
The Effects of Metals and Interfering Fields on Electromagnetic Trackers
Nixon, M. A., McCallum, B. C., Fright, W. R., & Price, N. B. (1998) · PRESENCE Virtual and Augmented Reality · doi:10.1162/105474698565587 · Cited by 122
Roetenberg, D., Baten, C. T. M., & Veltink, P. H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903946 · Cited by 115
Self-citationVeltink, P. H., Slycke, P., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. J. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 101
Self-citationAmbulatory Low Back Load Exposure Estimation
Baten, C. T. M. (2000) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120004402855 · Cited by 10
Cited by
(2009) · Cited by 701
Nweke, H. F., Teh, Y. W., Mujtaba, G., & Al-garadi, M. A. (2019) · Information Fusion · doi:10.1016/j.inffus.2018.06.002 · Cited by 394
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Metadata
- Authors
- Roetenberg, D., Slycke, P. J., & Veltink, P. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-05
- Volume
- 54
- Issue
- 5
- Pages
- 883-890
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2105320369
- Cited by
- 334
- References
- 21
- FWCI
- 39.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.