The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Design of patient-specific gait modifications for knee osteoarthritis rehabilitation
Open accessAbstract
Abstract-Gait modification is a nonsurgical approach for reducing the external knee adduction torque in patients with knee osteoarthritis (OA). The magnitude of the first adduction torque peak in particular is strongly associated with knee OA progression. While toeing out has been shown to reduce the second peak, no clinically realistic gait modifications have been identified that effectively reduce both peaks simultaneously. This study predicts novel patient-specific gait modifications that achieve this goal without changing the foot path. The modified gait motion was designed for a single patient with knee OA using dynamic optimization of a patient-specific, full-body gait model. The cost function minimized the knee adduction torque subject to constraints limiting how much the new gait motion could deviate from the patient's normal gait motion. The optimizations predicted a "medial-thrust" gait pattern that reduced the first adduction torque peak between 32% and 54% and the second peak between 34% and 56%. The new motion involved three synergistic kinematic changes: slightly decreased pelvis obliquity, slightly increased leg flexion, and slightly increased pelvis axial rotation. After gait retraining, the patient achieved adduction torque reductions of 39% to 50% in the first peak and 37% to 55% in the second one. These reductions are comparable to those reported after high tibial osteotomy surgery. The associated kinematic changes were consistent with the predictions except for pelvis obliquity, which showed little change. This study demonstrates that it is feasible to design novel patient-specific gait modifications with potential clinical benefit using dynamic optimization of patient-specific, full-body gait models. Further investigation is needed to assess the extent to which similar gait modifications may be effective for other patients with knee OA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters
de Leva, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00178-6 · Cited by 2,958
Miyazaki, T., Wada, M., Kawahara, H., Sato, M., Baba, H., & Shimada, S. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.7.617 · Cited by 1,441
Dynamic Optimization of Human Walking
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392310 · Cited by 1,107
Interaction between active and passive knee stabilizers during level walking
Schipplein, O. D., & Andriacchi, T. P. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090114 · Cited by 1,019
Griewank, A., Juedes, D. W., & Utke, J. (1996) · ACM Transactions on Mathematical Software · doi:10.1145/229473.229474 · Cited by 746
Sharma, L., Hurwitz, D. E., Thonar, E. J.-M. A., Sum, J. A., Lenz, M. E., Dunlop, D. D., Schnitzer, T. J., Kirwan-Mellis, G., & Andriacchi, T. P. (1998) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199807)41:7<1233::aid-art14>3.0.co;2-l · Cited by 708
The Impact of Osteoarthritis: Implications for Research
Buckwalter, J. A., Saltzman, C., & Brown, T. (2004) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000143938.30681.9d · Cited by 678
A Dynamic Optimization Solution for Vertical Jumping in Three Dimensions
ANDERSON, F. C., & PANDY, M. G. (1999) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255849908907988 · Cited by 573
Andriacchi, T. P. (1994) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)31924-6 · Cited by 528
Zhao, D., Banks, S. A., Mitchell, K. H., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20379 · Cited by 520
Self-citationA relationship between gait and clinical changes following high tibial osteotomy.
Prodromos, C. C., Andriacchi, T. P., & Galante, J. O. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00007 · Cited by 442
Dynamic knee loads during gait predict proximal tibial bone distribution
Hurwitz, D. E., Sumner, D. R., Andriacchi, T. P., & Sugar, D. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00028-1 · Cited by 316
Altered hamstring-quadriceps muscle balance in patients with knee osteoarthritis
Hortobágyi, T., Westerkamp, L. M., Beam, S. L., Moody, J., Garry, J. P., Holbert, D., & DeVita, P. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.08.004 · Cited by 258
Determination of patient-specific multi-joint kinematic models through two-level optimization
Reinbolt, J. A., Schutte, J. F., Fregly, B. J., Koh, B. I., Haftka, R. T., George, A. D., & Mitchell, K. H. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.031 · Cited by 233
Self-citationIn vivo determination of the anatomical axes of the ankle joint complex: An optimization approach
van den Bogert, A. J., Smith, G. D., & Nigg, B. M. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90197-x · Cited by 199
Neptune, R. R., Wright, I. C., & van den Bogert, A. J. (2000) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840008915275 · Cited by 136
Talbot, L. A., Gaines, J. M., Ling, S. M., & Metter, E. J. (2003) · PubMed · Cited by 107
Determination of joint functional axes from noisy marker data using the finite helical axis
Chèze, L., Fregly, B. J., & Dimnet, J. (1998) · Human Movement Science · doi:10.1016/s0167-9457(97)00018-3 · Cited by 59
Self-citationMotion transformation by physically based spacetime optimization
Popović, Z., & Witkin, A. (1999) · Cited by 13
Cited by
Flexing Computational Muscle: Modeling and Simulation of Musculotendon Dynamics
Millard, M., Uchida, T., Seth, A., & Delp, S. L. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023390 · Cited by 651
Zhao, D., Banks, S. A., Mitchell, K. H., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20379 · Cited by 520
Self-citationToward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443
Decreased knee adduction moment does not guarantee decreased medial contact force during gait
Walter, J. P., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2010) · Journal of Orthopaedic Research · doi:10.1002/jor.21142 · Cited by 367
Self-citationGait modification strategies for altering medial knee joint load: A systematic review
Simic, M., Hinman, R. S., Wrigley, T. V., Bennell, K. L., & Hunt, M. A. (2011) · Arthritis Care & Research · doi:10.1002/acr.20380 · Cited by 278
Metadata
- Authors
- Fregly, B. J., Reinbolt, J. A., Rooney, K. L., Mitchell, K. H., & Chmielewski, T. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-09
- Volume
- 54
- Issue
- 9
- Pages
- 1687-1695
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2116531629
- Cited by
- 259
- References
- 19
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.