Breathing Detection: Towards a Miniaturized, Wearable, Battery-Operated Monitoring System

Corbishley, Phil, Rodriguez-Villegas, Esther·2008·IEEE Transactions on Biomedical Engineering

Abstract

This paper analyzes the main challenges associated with noninvasive, continuous, wearable, and long-term breathing monitoring. The characteristics of an acoustic breathing signal from a miniature sensor are studied in the presence of sources of noise and interference artifacts that affect the signal. Based on these results, an algorithm has been devised to detect breathing. It is possible to implement the algorithm on a single integrated circuit, making it suitable for a miniature sensor device. The algorithm is tested in the presence of noise sources on five subjects and shows an average success rate of 91.3% (combined true positives and true negatives).

Integrity signals

Registry

Crossref · 10.1109/tbme.2007.910679

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Corbishley et al. developed a system to measure respiratory rate using a miniaturized wearable acoustic sensor (microphone).

    “Another example of ingenious design is the system developed by Corbishley et al. [24] to measure respiratory rate using a miniaturized wearable acoustic sensor (i.e. microphone).”
  • The authors also presented an algorithm for the detection of apneas based on the acoustic sensing technology.

    “The authors also presented an algorithm for the detection of apneas based on the above-described sensing technology.”
  • By developing techniques to filter out environmental noise and other artifacts, the authors achieved accuracy greater than 90% in the measurement of breathing rate.

    “By developing techniques to filter out environmental noise and other artifacts, the authors managed to achieve accuracy greater than 90% in the measurement of breathing rate.”

Cites

Flagged first, then by citations

2 of the 22 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Corbishley, P., & Rodriguez-Villegas, E.
Affiliations
Imperial College London (GB)
Venue
IEEE Transactions on Biomedical Engineering
Published
2008-01
Volume
55
Issue
1
Pages
196-204
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2135517513
Cited by
221
References
22
Citations by year
2026: 2 · 2025: 4 · 2024: 13 · 2023: 19 · 2022: 8 · 2021: 13 · 2020: 12 · 2019: 24 · 2018: 20 · 2017: 24 · 2016: 16 · 2015: 19 · 2014: 15 · 2013: 9 · 2012: 7
FWCI
2.63
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
breathing detection, wearable sensors, non-invasive monitoring, signal processing algorithms, integrated circuit implementation, long-term physiological monitoring
MeSH terms
Acoustics, Auscultation, Diagnosis, Computer-Assisted, Equipment Design, Humans, Miniaturization, Electric Power Supplies, Respiratory Sounds, Sound Spectrography, Transducers, Respiratory Mechanics, Monitoring, Ambulatory, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review