The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Principal Components Analysis Preprocessing for Improved Classification Accuracies in Pattern-Recognition-Based Myoelectric Control
Abstract
Information extracted from multiple channels of the surface myoelectric signal (MES) recording sites can be used as inputs to control systems for powered upper limb prostheses. For small, closely spaced muscles, such as the muscles in the forearm, the detected MES often contains contributions from more than one muscle, the contribution from each specific muscle being modified by the dispersive propagation through the volume conductor between the muscle and the detection points. In this paper, the measured raw MES signals are rotated by class-specific principal component matrices to spatially decorrelate the measured data prior to feature extraction. This "tunes" the data to allow a pattern recognition classifier to better discriminate the test motions. This processing technique was used to significantly ( p < 0.01) reduce pattern recognition classification error for both intact limbed and transradial amputee subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 2×
“Pattern-recognitionbased myoelectric control systems operate on the assumption that at a given electrode location, the set of features describing the MES will be repeatable for a given state of muscle activation and will also be different from one state of activation to another [ 7 ].”
BackgroundMicera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Research works printed but not linked: 29
- 10.1109/TNSRE.2007.891391 · DOI · Paper page
- 10.1109/TRA.2003.808873 · DOI · Paper page
- 10.1016/S0167-8655(99)00083-5 · DOI · Paper page
- owens, 2004, Atlas of Amputations and Limb Deficiencies, 219
- 10.1097/00008526-199600810-00003 · DOI · Paper page
- childress, 2004, Atlas of Amputations and Limb Deficiencies Surgical Prosthetic and Rehabilitation Principles, 173
- 10.1109/10.1370 · DOI
- 10.1109/10.634653 · DOI
- 10.1109/10.914793 · DOI · Paper page
- chan, 2007, myoelectric control development toolbox, Proc 23rd Canadian Medical and Biological Engineering Society Conf
- bellman, 1961, Adaptive Control Processes, 10.1515/9781400874668 · DOI · Paper page
- 10.1109/TSMCC.2005.848183 · doi:10.1109/tsmcc.2005.848183
- childress, 1969, a myoelectric three state controller using rate sensitivity, Proc 8th ICMBE, 4s
- 10.1016/S0031-3203(02)00033-X · doi:10.1016/s0031-3203(02)00033-x
- 10.1007/BF02476154 · DOI
- kuiken, 2004, the use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee, Prosthet Orthot Int, 28, 245, 10.3109/03093640409167756 · DOI · Paper page
- 10.1109/IEMBS.2007.4353853 · doi:10.1109/iembs.2007.4353853
- 10.1109/TNANO.2008.2005187 · DOI
- 10.1109/TBME.2006.889192 · DOI · Paper page
- kobrinski, 1960, Automatic and Remote Control Proc 1st IFAC Int Congr, 2, 619
- 10.1109/TBME.2005.856295 · DOI · Paper page
- 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- 10.1016/S1350-4533(99)00066-1 · DOI · Paper page
- 10.1109/86.867872 · DOI · Paper page
- 10.1109/TBME.2004.836492 · DOI · Paper page
- farry, 1997, applying genetic programming to control of an artificial arm, Proc Myoelectric Control (MEC 1997) Conf, 50
- 10.1109/IEMBS.2003.1279711 · DOI
- 10.1002/0471221317 · DOI · Paper page
- 10.1109/TBME.2008.2010392 · DOI
Cited by
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
Lower Limb Wearable Capacitive Sensing and Its Applications to Recognizing Human Gaits
Zheng, E., Chen, B., Wei, K., & Wang, Q. (2013) · Sensors · doi:10.3390/s131013334 · Cited by 26
Metadata
- Authors
- Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-05
- Volume
- 56
- Issue
- 5
- Pages
- 1407-1414
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2120395111
- Cited by
- 211
- References
- 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.