A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A conceptually novel prosthesis consisting of a mechatronic hand, an electromyographic classifier, and a tactile display has been developed and evaluated by addressing problems related to controllability in prosthetics: intention extraction, perception, and feeling of ownership. Experiments have been performed, and encouraging results for a young transradial amputee are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rubber hands ‘feel’ touch that eyes see
Botvinick, M., & Cohen, J. (1998) · Nature · doi:10.1038/35784 · Cited by 4,410 · cited 4×
“In the rubber-hand illusion [14], synchronous brushstrokes, applied to a rubber hand in full view and to the participant’s real hand, which is hidden under a table or behind a screen, produce the experience that the touch is located on the rubber hand and that the rubber hand is one’s own hand.”
BackgroundMethodInfluentialJia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70 · cited 1×
“In [5] and [6] direct neural feedback and control of an artificial arm in amputees have been achieved using surgical implanted peripheral neural interfaces.”
Method
Cited by
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
“Several research groups have measured the movements of the contralateral hand with a data glove and used it for proportional control [67] or on–off control [128].”
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Self-citationSurface EMG pattern recognition for real-time control of a wrist exoskeleton
Khokhar, Z. O., Xiao, Z. G., & Menon, C. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-41 · Cited by 258
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
“The results from an offline analysis from participant have been previously documented in [ 25 ].”
MethodSelf-citation
Metadata
- Authors
- Cipriani, C., Antfolk, C., Balkenius, C., Rosen, B., Lundborg, G., Carrozza, M. C., & Sebelius, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 2739-2743
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2100830232
- Cited by
- 48
- References
- 2
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study. https://app.cochat.ai/papers/10.1109/tbme.2009.2031242
- The paper
- Cipriani, C., Antfolk, C., Balkenius, C., Rosen, B., Lundborg, G., Carrozza, M. C., & Sebelius, F. (2009). A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2009.2031242
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.