An Online Self-Tunable Method to Denoise CGM Sensor Data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) devices can be very useful in diabetes management. Unfortunately, their use in online applications, e.g., for hypo/hyperalert generation, is made difficult by random noise measurement. Remarkably, the SNR of CGM data varies with the sensor and with the individual. As a consequence, approaches in which filter parameters are not allowed to adapt to the current SNR are likely to be suboptimal. In this paper, we present a new online methodology to reduce noise in CGM signals by a Kalman filter (KF), whose unknown parameters are adjusted in a given individual by a stochastically based smoothing criterion exploiting data of a burn-in interval. The performance of the new KF approach is quantitatively assessed on Monte Carlo simulations and 24 real CGM datasets. Our results are compared with those obtained by a moving-average (MA) filtering approach with fixed parameters currently in use in likely all commercial CGM devices. Results show that the new KF approach performs much better than MA. For instance, on real data, for comparable signal denoising, the delay introduced by KF is about 35% less than that obtained by MA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Self-citationA stochastic deconvolution method to reconstruct insulin secretion rate after a glucose stimulus
Sparacino, G., & Cobelli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488799 · Cited by 76
Self-citation
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“Monte Carlo simulation of [225] and obtained by adding,”
Self-citationContinuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“In the implementation, we proposed in Facchinetti et al. [27], that the denoising module contained an adaptive self-tunable Bayesian smoother [29,30] able to automatically estimate in real time the signal-to-noise ratio present on the CGM data and able to perform an optimal and computationally…”
MethodSelf-citation
Metadata
- Authors
- Facchinetti, A., Sparacino, G., & Cobelli, C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-03
- Volume
- 57
- Issue
- 3
- Pages
- 634-641
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2121201523
- Cited by
- 62
- References
- 2
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Online Self-Tunable Method to Denoise CGM Sensor Data. https://app.cochat.ai/papers/10.1109/tbme.2009.2033264
- The paper
- Facchinetti, A., Sparacino, G., & Cobelli, C. (2010). An Online Self-Tunable Method to Denoise CGM Sensor Data. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2009.2033264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.