CoChat

PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children

Gil, Eduardo, Bailon, Raquel, Vergara, Jose Maria, Laguna, Pablo · 2010 · IEEE Transactions on Biomedical Engineering
Cited by 88

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In this paper, an analysis of pulse transit time variability (PTTV) during decreases in the amplitude fluctuations of pulse photoplethysmography signal (PPG) (DAP) events for obstructive sleep apnea syndrome (OSAS) screening is presented. The temporal evolution of time-frequency PTTV parameters during DAP was analyzed. The results show an increase in the sympathetic activity index low-frequency component (LF) during DAP for PTTV (85%) significantly higher than for heart rate variability (HRV) (33%), (p < 10(-13)). However, decreases in parasympathetic activity produce lower decrements in high-frequency component (HF) indexes for PTTV (18%) than for HRV (22%). Thus, PTTV reflects sympathetic changes more clearly than HRV. A clinical study was carried out. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the PTTV indexes. The ratio of DAP events per hour r (DAP), the ratio after filtering based on HRV indexes r (HRV) (DAP), or on PTTV indexes r (PTTV) (DAP), were computed. The results show an accuracy of 75% for r (PTTV) (DAP) (14% increase with respect to r (DAP) and 5% increase with respect to r (HRV) (DAP)), a sensitivity of 81.8%, and a specificity of 73.9% when classifying 1-h polysomnographic excerpts as OSAS or normal. These results suggest that the combination of DAP and PTTV could be better alternative for sleep apnea screening using PPG with the added benefit of its low cost and simplicity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2009.2037734

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 88

Metadata

Authors
Gil, E., Bailon, R., Vergara, J. M., & Laguna, P.
Venue
IEEE Transactions on Biomedical Engineering
Published
2010-05
Volume
57
Issue
5
Pages
1079-1088
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2130465845
Cited by
88
References
5
FWCI
3.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children. https://app.cochat.ai/papers/10.1109/tbme.2009.2037734
The paper
Gil, E., Bailon, R., Vergara, J. M., & Laguna, P. (2010). PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2009.2037734

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.