The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Novel Breath Analysis System Based on Electronic Olfaction
Abstract
Certain gases in the breath are known to be indicators of the presence of diseases and clinical conditions. These gases have been identified as biomarkers using equipments such as gas chromatography (GC) and electronic nose (e-nose). GC is very accurate but is expensive, time consuming, and non-portable. E-nose has the advantages of low-cost and easy operation, but is not particular for analyzing breath odor and hence has a limited application in diseases diagnosis. This article proposes a novel system that is special for breath analysis. We selected chemical sensors that are sensitive to the biomarkers and compositions in human breath, developed the system, and introduced the odor signal preprocessing and classification method. To evaluate the system performance, we captured breath samples from healthy persons and patients known to be afflicted with diabetes, renal disease, and airway inflammation repectively and conducted experiments on medical treatment evaluation and disease identification. The results show that the system is not only able to distinguish between breath samples from subjects suffering from various diseases or conditions (diabetes, renal disease, and airway inflammation) and breath samples from healthy subjects, but in the case of renal failure is also helpful in evaluating the efficacy of hemodialysis (treatment for renal failure).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Colonic fermentation of indigestible carbohydrates contributes to the second-meal effect
Brighenti, F., Benini, L., Del Rio, D., Casiraghi, C., Pellegrini, N., Scazzina, F., Jenkins, D. J., & Vantini, I. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.4.817 · Cited by 213
Cited by
Feature selection and analysis on correlated gas sensor data with recursive feature elimination
Yan, K., & Zhang, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.02.025 · Cited by 516
Self-citationAdvances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, S.-W., & Tang, K.-T. (2013) · Sensors · doi:10.3390/s131014214 · Cited by 242
Electronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105
Metadata
- Authors
- Guo, D., Zhang, D., Li, N., Zhang, L., & Yang, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-11
- Volume
- 57
- Issue
- 11
- Pages
- 2753-2763
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2118045199
- Cited by
- 178
- References
- 2
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.