The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Selective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Abstract
Recent literature in pattern recognition-based myoelectric control has highlighted a disparity between classification accuracy and the usability of upper limb prostheses. This paper suggests that the conventionally defined classification accuracy may be idealistic and may not reflect true clinical performance. Herein, a novel myoelectric control system based on a selective multiclass one-versus-one classification scheme, capable of rejecting unknown data patterns, is introduced. This scheme is shown to outperform nine other popular classifiers when compared using conventional classification accuracy as well as a form of leave-one-out analysis that may be more representative of real prosthetic use. Additionally, the classification scheme allows for real-time, independent adjustment of individual class-pair boundaries making it flexible and intuitive for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nearest neighbor pattern classification
Cover, T., & Hart, P. (1967) · IEEE Transactions on Information Theory · doi:10.1109/tit.1967.1053964 · Cited by 16,936
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Research works printed but not linked: 27
- van der heijden, 2004, Classification Parameter Estimation and State Estimation An Engineering Approach Using MATLAB, 10.1002/0470090154 · DOI · Paper page
- 10.1214/aoms/1177704472 · DOI · Paper page
- 10.1109/TBME.2008.919734 · DOI · Paper page
- lucas, 2008, Multi-channel surface EMG classification using support vector machines and signal-based wavelet optimization, Biomed Signal Process Control, 3, 169, 10.1016/j.bspc.2007.09.002 · DOI · Paper page
- 10.1109/TBME.2005.856295 · DOI · Paper page
- 10.1109/10.204774 · DOI · Paper page
- 10.1109/10.914793 · DOI · Paper page
- 10.1016/S1350-4533(99)00066-1 · DOI · Paper page
- 10.1109/TBME.2006.883695 · DOI · Paper page
- 10.1109/TNSRE.2009.2039590 · DOI · Paper page
- 10.1109/IEMBS.2007.4353424 · DOI
- finley, 1967, Myocoder studies of multiple myopotential response, Arch Phys Med Rehabil, 48, 598
- 10.1109/TBME.2008.2008171 · DOI · Paper page
- childress, 1969, A myoelectric three state controller using rate sensitivity, Proc Int Conf Engineering in Medicine and Biology, 4s
- 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- 10.1023/A:1009715923555 · DOI · Paper page
- atkins, 1993, Retrospective analysis of 87 children and adults fitted with electric prosthetic componentry, Proc Assoc Children's Prosthetic-Orthotic Clinics Conf, 4
- 10.1109/TBME.2006.889192 · DOI · Paper page
- 10.1007/BF02476154 · DOI
- battye, 1955, The use of myoelectric current in the operation of prostheses, J Bone Joint Surg, 37b, 506, 10.1302/0301-620X.37B3.506 · DOI
- 10.1001/jama.2009.116 · DOI · Paper page
- 10.1109/IEMBS.2010.5627638 · DOI · Paper page
- 10.1016/j.bspc.2007.11.005 · DOI · Paper page
- lock, 2005, Real-time myoelectric control in a virtual environment to relate usability vs. accuracy, Proc Myoelectric Control (MEC) Conf, 122
- boschmann, 2009, Towards multi-movement hand prostheses: Combining adaptive classification with high precision socket, Proc 2nd Eur Conf Technically Assisted Rehabil
- ye, 2004, Using uncorrelated discriminant analysis for tissue classification with gene expression data, IEEE Trans Comput Biol Bioinformatics, 1, 181, 10.1109/TCBB.2004.45 · DOI · Paper page
- 10.1109/FGR.2006.91 · doi:10.1109/fgr.2006.91
Cited by
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Characterization of a Benchmark Database for Myoelectric Movement Classification
Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328495 · Cited by 293
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Metadata
- Authors
- Scheme, E. J., Englehart, K. B., & Hudgins, B. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-06
- Volume
- 58
- Issue
- 6
- Pages
- 1698-1705
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2170034570
- Cited by
- 172
- References
- 4
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.