The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift
Open accessAbstract
Myoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p < 0.01). Another finding was the significant difference (p < 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationSupport Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Self-citationXu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
Evaluating EMG feature and classifier selection for application to partial-hand prosthesis control
Adewuyi, A. A., Hargrove, L. J., & Kuiken, T. A. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00015 · Cited by 85
Self-citationVu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Leveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models
Hodossy, B. K., Guez, A. S., Jing, S., Huo, W., Vaidyanathan, R., & Farina, D. (2024) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2024.3371099 · Cited by 10
Metadata
- Authors
- Young, A. J., Hargrove, L. J., & Kuiken, T. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-09
- Volume
- 58
- Issue
- 9
- Pages
- 2537-2544
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2138967075
- Cited by
- 287
- References
- 34
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.