Online Denoising Method to Handle Intraindividual Variability of Signal-to-Noise Ratio in Continuous Glucose Monitoring
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In the last decade, the availability of new minimally invasive subcutaneous sensors for monitoring glucose level continuously stimulated research on new online strategies for improving the treatment of diabetes, including hyper/hypoglycemic alert generators and artificial pancreas. An important aspect that has to be dealt with in these applications is the random measurement noise that affects continuous glucose monitoring (CGM) signals. One major difficulty is that for a given sensor technology, the signal-to-noise ratio (SNR) can vary from subject to subject (interindividual variability) and also within subject (intraindividual variability). Recently, a denoising approach implemented through a Kalman filter with parameters automatically tuned, once for all, in a burn-in interval was proposed to cope with the interindividual variability of SNR. In this paper, we propose a new denoising method able to cope also with the intraindividual variability of the SNR. The method resorts to a Bayesian smoothing procedure that uses a statistically-based criterion to determine, and continuously update, filter parameters in real time. The performance of the method is assessed on both Monte Carlo simulation and 24 real CGM time series obtained with the Glucoday system (Menarini, Florence, Italy). The method has a general applicability, also outside from the CGM context.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Self-citationRebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
A stochastic deconvolution method to reconstruct insulin secretion rate after a glucose stimulus
Sparacino, G., & Cobelli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488799 · Cited by 76
Self-citation
Cited by
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“[27], that the denoising module contained an adaptive self-tunable Bayesian smoother [29,30] able to automatically estimate in real time the signal-to-noise ratio present on the CGM data and able to perform an optimal and computationally efficient real-time smoothing thanks to a Kalman filter-based implementation.”
MethodSelf-citationModeling the glucose sensor error
Facchinetti, A., Del Favero, S., Sparacino, G., Castle, J. R., Ward, W. K., & Cobelli, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2284023 · Cited by 130
“, the Bayesian denoising algorithm of [26] when”
MethodSelf-citationFacchinetti, A., Favero, S., Sparacino, G., & Cobelli, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227256 · Cited by 62
Self-citationCamerlingo, N., Vettoretti, M., Del Favero, S., Cappon, G., Sparacino, G., & Facchinetti, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0139 · Cited by 22
Self-citationCaduff, A., Zanon, M., Zakharov, P., Mueller, M., Talary, M., Krebs, A., Stahel, W. A., & Donath, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817750932 · Cited by 17
Metadata
- Authors
- Facchinetti, A., Sparacino, G., & Cobelli, C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-09
- Volume
- 58
- Issue
- 9
- Pages
- 2664-2671
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2139057798
- Cited by
- 58
- References
- 5
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.