The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Automatic Motion and Noise Artifact Detection in Holter ECG Data Using Empirical Mode Decomposition and Statistical Approaches
Abstract
We present a real-time method for the detection of motion and noise (MN) artifacts, which frequently interferes with accurate rhythm assessment when ECG signals are collected from Holter monitors. Our MN artifact detection approach involves two stages. The first stage involves the use of the first-order intrinsic mode function (F-IMF) from the empirical mode decomposition to isolate the artifacts' dynamics as they are largely concentrated in the higher frequencies. The second stage of our approach uses three statistical measures on the F-IMF time series to look for characteristics of randomness and variability, which are hallmark signatures of MN artifacts: the Shannon entropy, mean, and variance. We then use the receiver-operator characteristics curve on Holter data from 15 healthy subjects to derive threshold values associated with these statistical measures to separate between the clean and MN artifacts' data segments. With threshold values derived from 15 training data sets, we tested our algorithms on 30 additional healthy subjects. Our results show that our algorithms are able to detect the presence of MN artifacts with sensitivity and specificity of 96.63% and 94.73%, respectively. In addition, when we applied our previously developed algorithm for atrial fibrillation (AF) detection on those segments that have been labeled to be free from MN artifacts, the specificity increased from 73.66% to 85.04% without loss of sensitivity (74.48%-74.62%) on six subjects diagnosed with AF. Finally, the computation time was less than 0.2 s using a MATLAB code, indicating that real-time application of the algorithms is possible for Holter monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Cited by
A Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
“Lee et al. [62] presented an automatic motion and noise artifact detection in Holter ECGs using EMD and statistical features such as Shannon entropy, mean, and variance of the first intrinsic mode function (IMF).”
MethodMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Self-citationSatija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140783 · Cited by 42
“Moreover, other techniques such as principal component (PCA) and independent component (ICA) analysis [39–42] as well as Empirical Mode Decomposition (EMD) [43, 44] have been explored, but nevertheless the MA issue needs to be still addressed.”
MethodA simple method for detection and classification of ECG noises for wearable ECG monitoring devices
Satija, U., Ramkumar, B., & Manikandan, M. S. (2015) · 2015 2nd International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2015.7095425 · Cited by 34
Metadata
- Authors
- Lee, J., McManus, D. D., Merchant, S., & Chon, K. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-06
- Volume
- 59
- Issue
- 6
- Pages
- 1499-1506
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2043365522
- Cited by
- 159
- References
- 1
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.