Automated Algorithm for Generalized Tonic–Clonic Epileptic Seizure Onset Detection Based on sEMG Zero-Crossing Rate
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Patients are not able to call for help during a generalized tonic-clonic epileptic seizure. Our objective was to develop a robust generic algorithm for automatic detection of tonic-clonic seizures, based on surface electromyography (sEMG) signals suitable for a portable device. Twenty-two seizures were analyzed from 11 consecutive patients. Our method is based on a high-pass filtering with a cutoff at 150 Hz, and monitoring a count of zero crossings with a hysteresis of ±50 μV . Based on data from one sEMG electrode (on the deltoid muscle), we achieved a sensitivity of 100% with a mean detection latency of 13.7 s, while the rate of false detection was limited to 1 false alarm per 24 h. The overall performance of the presented generic algorithm is adequate for clinical implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fisher, R. S., Boas, W. V. E., Blume, W., Elger, C., Genton, P., Lee, P., & Engel, J. (2005) · Epilepsia · doi:10.1111/j.0013-9580.2005.66104.x · Cited by 3,671
Nijsen, T. M. E., Arends, J. B. A. M., Griep, P. A. M., & Cluitmans, P. J. M. (2005) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2005.04.011 · Cited by 139
Cited by
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Multicenter clinical assessment of improved wearable multimodal convulsive seizure detectors
Onorati, F., Regalia, G., Caborni, C., Migliorini, M., Bender, D., Poh, M., Frazier, C., Kovitch Thropp, E., Mynatt, E. D., Bidwell, J., et al. (2017) · Epilepsia · doi:10.1111/epi.13899 · Cited by 212
Automated real-time detection of tonic-clonic seizures using a wearable EMG device
Beniczky, S., Conradsen, I., Henning, O., Fabricius, M., & Wolf, P. (2018) · Neurology · doi:10.1212/wnl.0000000000004893 · Cited by 171
“Our intention was to record GTCS from 20 patients, with a total of at least 30 GTCS.”
MethodInfluentialSelf-citationGubbi, J., Kusmakar, S., Rao, A. S., Yan, B., OBrien, T., & Palaniswami, M. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2446539 · Cited by 41
“Further, Conradsen et al. [18] have shown the efficacy of sEMG in the automated detection of general tonic–clonic seizures with a very high sensitivity of 100% and a specificity of 1 false detection per day.”
BackgroundBöttcher, S., Bruno, E., Manyakov, N. V., Epitashvili, N., Claes, K., Glasstetter, M., Thorpe, S., Lees, S., Dümpelmann, M., Van Laerhoven, K., et al. (2021) · JMIR mHealth and uHealth · doi:10.2196/27674 · Cited by 39
“Finally, electromyography is a self-evident modality for detecting seizures with motor components, identifying ictal muscle contraction, and thus has been used for convulsive seizure detection as well [25-28].”
Method
Metadata
- Authors
- Conradsen, I., Beniczky, S., Hoppe, K., Wolf, P., & Sorensen, H. B. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-02
- Volume
- 59
- Issue
- 2
- Pages
- 579-585
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2056488712
- Cited by
- 96
- References
- 2
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.