Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 453

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

A Robust and Sensitive Metric for Quantifying Movement Smoothness

Balasubramanian, S., Melendez-Calderon, A., Burdet, E.·2012·IEEE Transactions on Biomedical Engineering

Abstract

The need for movement smoothness quantification to assess motor learning and recovery has resulted in various measures that look at different aspects of a movement's profile. This paper first shows that most of the previously published smoothness measures lack validity, consistency, sensitivity, or robustness. It then introduces and evaluates the spectral arc-length metric that uses a movement speed profile's Fourier magnitude spectrum to quantify movement smoothness. This new metric is systematically tested and compared to other smoothness metrics, using experimental data from stroke and healthy subjects as well as simulated movement data. The results indicate that the spectral arc-length metric is a valid and consistent measure of movement smoothness, which is both sensitive to modifications in motor behavior and robust to measurement noise. We hope that the systematic analysis of this paper is a step toward the standardization of the quantitative assessment of movement smoothness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2179545

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Balasubramanian, S., Melendez-Calderon, A., & Burdet, E.
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-08
Volume
59
Issue
8
Pages
2126-2136
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2030742234
Cited by
453
References
11
FWCI
3.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.