Photoplethysmography: A measure for the function of the autonomic nervous system in focal impaired awareness seizures
Abstract
Objectives: Photoplethysmography (PPG) reflects variations of blood perfusion in tissues, which may signify seizure‐related autonomic changes. The aim of this study is to assess the variability of PPG signals and their value in detecting peri‐ictal changes in patients with focal impaired awareness seizures (FIASs). Methods: PPG data were recorded using a wearable sensor placed on the wrist or ankle of children with epilepsy admitted for long‐term video‐electroencephalographic monitoring. We analyzed PPG data in four different periods: seizure‐free, preictal, ictal, and postictal. Multiple features were automatically extracted from the PPG signal—frequency, duration, amplitude, increasing and decreasing slopes, smoothness, and area under the curve (AUC)—and were used to identify preictal, ictal, or postictal changes by comparing them with seizure‐free periods and with each other using a linear mixed‐effects model. Results: We studied PPG in 11 patients (18 FIASs), including seizure‐free, preictal, and postictal periods, and a subset of eight patients (12 FIASs) including the ictal period. Compared to the seizure‐free period, we found significant changes in PPG (1) during the ictal period across all features; (2) during the preictal period in amplitude, duration, increasing slope, and AUC; and (3) during the postictal period in decreasing slope. Significance: Specific PPG changes can be seen before, during, and after FIASs. The peri‐ictal changes in the PPG features of patients with FIASs suggest potential applications of PPG monitoring for seizure detection.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In another study assessing PPG as a measure for epileptic seizures, the data from three out of eleven patients wearing an Empatica E4 device was not usable, since no seizure periods without motion artifacts could be recorded.
“In another study assessing PPG as a measure for epileptic seizures, the data from three out of eleven patients wearing an Empatica E4 device was not usable, since no seizure periods without motion artifacts could be recorded69.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [69]
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469 · see citing works
Self-citationA Robust and Sensitive Metric for Quantifying Movement Smoothness
Balasubramanian, S., Melendez-Calderon, A., & Burdet, E. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2179545 · Cited by 454 · see citing works
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403 · see citing works
Cardiac arrhythmias in focal epilepsy: a prospective long-term study
Rugg-Gunn, F. J., Simister, R. J., Squirrell, M., Holdright, D. R., & Duncan, J. S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17594-6 · Cited by 384 · see citing works
Convulsive seizure detection using a wrist‐worn electrodermal activity and accelerometry biosensor
Poh, M., Loddenkemper, T., Reinsberger, C., Swenson, N. C., Goyal, S., Sabtala, M. C., Madsen, J. R., & Picard, R. W. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03444.x · Cited by 272 · see citing works
Self-citationNeural control of muscle blood flow during exercise
Thomas, G. D., & Segal, S. S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00076.2004 · Cited by 257 · see citing works
Ictal tachycardia: The head–heart connection
Eggleston, K. S., Olin, B., & Fisher, R. S. (2014) · Seizure · doi:10.1016/j.seizure.2014.02.012 · Cited by 242 · see citing works
Autonomic changes with seizures correlate with postictal EEG suppression
Poh, M., Loddenkemper, T., Reinsberger, C., Swenson, N. C., Goyal, S., Madsen, J. R., & Picard, R. W. (2012) · Neurology · doi:10.1212/wnl.0b013e318258f7f1 · Cited by 242 · see citing works
Self-citationRegalia, G., Onorati, F., Lai, M., Caborni, C., & Picard, R. W. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.007 · Cited by 240 · see citing works
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233 · see citing works
Self-citationThe peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 231 · see citing works
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230 · see citing works
Detection of seizure-like movements using a wrist accelerometer
Lockman, J., Fisher, R. S., & Olson, D. M. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.01.019 · Cited by 195 · see citing works
Wearable technology in epilepsy: The views of patients, caregivers, and healthcare professionals
Bruno, E., Simblett, S., Lang, A., Biondi, A., Odoi, C., Schulze-Bonhage, A., Wykes, T., & Richardson, M. P. (2018) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2018.05.044 · Cited by 191 · see citing works
Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment
Vandecasteele, K., De Cooman, T., Gu, Y., Cleeren, E., Claes, K., Paesschen, W., Huffel, S., & Hunyadi, B. (2017) · Sensors · doi:10.3390/s17102338 · Cited by 174 · see citing works
Automated real-time detection of tonic-clonic seizures using a wearable EMG device
Beniczky, S., Conradsen, I., Henning, O. J., Fabricius, M. E., & Wolf, P. (2018) · Neurology · doi:10.1212/wnl.0000000000004893 · Cited by 171 · see citing works
The incidence and significance of periictal apnea in epileptic seizures
Lacuey, N., Zonjy, B., Hampson, J. P., Rani, M. R. S., Zaremba, A., Sainju, R. K., Gehlbach, B. K., Schuele, S., Friedman, D. J., Devinsky, O., et al. (2018) · Epilepsia · doi:10.1111/epi.14006 · Cited by 160 · see citing works
Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140 · see citing works
Gu, Y., Cleeren, E., Dan, J., Claes, K., Paesschen, W. V., Huffel, S. V., & Hunyadi, B. (2017) · Sensors · doi:10.3390/s18010029 · Cited by 132 · see citing works
Seizure detection based on heart rate variability using a wearable electrocardiography device
Jeppesen, J., Fuglsang‐Frederiksen, A., Johansen, P., Christensen, J., Wüstenhagen, S., Tankişi, H., Qerama, E., Heß, A., & Beniczky, S. (2019) · Epilepsia · doi:10.1111/epi.16343 · Cited by 116 · see citing works
Pre-ictal heart rate changes: A systematic review and meta-analysis
Bruno, E., Biondi, A., & Richardson, M. P. (2018) · Seizure · doi:10.1016/j.seizure.2018.01.003 · Cited by 66 · see citing works
Pietilä, J., Mehrang, S., Tolonen, J., Helander, E. E., Jimison, H. B., Misha Pavel, C., & Korhonen, I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_37 · Cited by 59 · see citing works
Behbahani, S., Dabanloo, N. J., Nasrabadi, A. M., Teixeira, C., & Dourado, A. (2013) · The Anatolian Journal of Cardiology · doi:10.5152/akd.2013.237 · Cited by 53 · see citing works
Ictal autonomic changes as a tool for seizure detection: a systematic review
van Westrhenen, A., Cooman, T. D., Lazeron, R. H. C., Huffel, S. V., & Thijs, R. D. (2018) · Clinical Autonomic Research · doi:10.1007/s10286-018-0568-1 · Cited by 53 · see citing works
Evaluation of the signal quality of wrist-based photoplethysmography
Pradhan, N., Rajan, S., & Adler, A. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab225a · Cited by 50 · see citing works
Seizure detection: do current devices work? And when can they be useful?
Zhao, X., & Lhatoo, S. D. (2018) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-018-0849-z · Cited by 29 · see citing works
Probability of detection of clinical seizures using heart rate changes
Osorio, I., & Manly, B. F. J. (2015) · Seizure · doi:10.1016/j.seizure.2015.06.007 · Cited by 28 · see citing works
Frequency analysis of photoplethysmogram and its derivatives
Elgendi, M., Fletcher, R., Norton, I., Brearley, M. B., Abbott, D., Lovell, N. H., & Schuurmans, D. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.09.021 · Cited by 28 · see citing works
An Automated System for the Analysis of Newborns’ Oral-Motor Behavior
Tamilia, E., Formica, D., Scaini, A., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2496150 · Cited by 27 · see citing works
Self-citationCardiac arrhythmias in focal epilepsy: A prospective long-term study
Rugg‐Gunn, F. J., Simister, R. J., Squirrell, M., et al. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.03.047 · Cited by 25 · see citing works
de Oliveira, G. R., Gondim, F. D. A. A., Hogan, R. E., & Rola, F. H. (2007) · Arquivos de Neuro-Psiquiatria · doi:10.1590/s0004-282x2007000400003 · Cited by 21 · see citing works
Peripheral multimodal monitoring of ANS changes related to epilepsy
Vieluf, S., Atrache, R. E., Hammond, S., Mohammadpour, F., Loddenkemper, T., & Reinsberger, C. (2019) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.02.018 · Cited by 20 · see citing works
Self-citationTamilia, E., Delafield, J., Fiore, S., et al. (2014) · doi:10.1109/embc.2014.6944934 · Cited by 14 · see citing works
Self-citationOrthostatic stress and area under the curve of photoplethysmography waveform
Zaidi, S. N., & Collins, S. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/4/045006 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Seizure detection using wearable sensors and machine learning: Setting a benchmark
Tang, J., El Atrache, R., Yu, S., Asif, U., Jackson, M., Roy, S., Mirmomeni, M., Cantley, S., Sheehan, T., Schubach, S., et al. (2021) · Epilepsia · doi:10.1111/epi.16967 · Cited by 146 · see citing works
Self-citationData quality evaluation in wearable monitoring
Böttcher, S., Vieluf, S., Bruno, E., Joseph, B., Epitashvili, N., Biondi, A., Zabler, N., Glasstetter, M., Dümpelmann, M., Van Laerhoven, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-25949-x · Cited by 91 · see citing works
Self-citation
- Authors
- El Atrache, R., Tamilia, E., Mohammadpour Touserkani, F., Hammond, S., Papadelis, C., Kapur, K., Jackson, M., Bucciarelli, B., Tsuboyama, M., Sarkis, R. A., & Loddenkemper, T.
- Affiliations
- Division of Epilepsy and Clinical Neurophysiology Department of Neurology Boston Children's Hospital Harvard Medical School Boston Massachusetts USA
- Boston Children's Hospital (US)
- Brigham and Women's Hospital (US)
- ORCID
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2020-07-25
- Volume
- 61
- Issue
- 8
- Pages
- 1617-1626
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W3045429206
- Cited by
- 16
- References
- 37
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 3
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Epilepsia (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Epilepsy Research Fund
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- photoplethysmography, complex partial seizures, autonomic nervous system, seizure detection, wearable sensors, pediatric epilepsy
- MeSH terms
- Wearable Electronic Devices, Adolescent, Ankle, Autonomic Nervous System, Child, Electroencephalography, Epilepsies, Partial, Female, Humans, Male, Wrist, Linear Models, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review