Electrocardiogram-Assisted Blood Pressure Estimation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Accurate automatic noninvasive assessment of blood pressure (BP) presents a challenge due to conditions like arrhythmias, obesity, and postural changes that tend to obfuscate arterial amplitude pulsations sensed by the cuff. Researchers tried to overcome this challenge by analyzing oscillometric pulses with the aid of a higher fidelity signal-the electrocardiogram (ECG). Moreover, pulse transit time (PTT) was employed to provide an additional method for BP estimation. However, these methods were not fully developed, suitably integrated, or tested. To address these issues, we present a novel method whereby ECG-assisted oscillometric and PTT (measured between ECG R-peaks and maximum slope of arterial pulse peaks) analyses are seamlessly integrated into the oscillometric BP measurement paradigm. The method bolsters oscillometric analysis (amplitude modulation) with more reliable ECG R-peaks provides a complementary measure with PTT analysis (temporal modulation) and fuses this information for robust BP estimation. We have integrated this technology into a prototype that comprises a BP cuff with an embedded conductive fabric ECG electrode, associated hardware, and algorithms. A pilot study has been undertaken on ten healthy subjects (150 recordings) to validate the performance of our prototype against United States Food and Drug Administration approved Omron oscillometric monitor (HEM-790IT). Our prototype achieves mean absolute difference of less than 5 mmHg and grade A as per the British Hypertension Society protocol for estimating BP, with the reference Omron monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · cited 1×
“erally weak and inconsistent [22]–[24].”
Cited by
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
“[5] and Xuan [6] showed that there is a significant correlation between BP and PTT, but this correlation depends on many parameters, which are varying among individuals [4], [7].”
BackgroundCuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Self-citationtinyCare: A tinyML-based Low-Cost Continuous Blood Pressure Estimation on the Extreme Edge
Ahmed, K., & Hassan, M. (2022) · 2022 IEEE 10th International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi54592.2022.00047 · Cited by 29
“Subsequent works deploy a preliminary fitting [28] or interpolation [29] approaches to empirically construct a mathematical function that fits the data of PWV/PPT and SBP.”
Background
Metadata
- Authors
- Ahmad, S., Chen, S., Soueidan, K., Batkin, I., Bolic, M., Dajani, H., & Groza, V.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-03
- Volume
- 59
- Issue
- 3
- Pages
- 608-618
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2162894545
- Cited by
- 104
- References
- 3
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrocardiogram-Assisted Blood Pressure Estimation. https://app.cochat.ai/papers/10.1109/tbme.2011.2180019
- The paper
- Ahmad, S., Chen, S., Soueidan, K., Batkin, I., Bolic, M., Dajani, H., & Groza, V. (2012). Electrocardiogram-Assisted Blood Pressure Estimation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2011.2180019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.