Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Engineering Challenges for Instrumenting and Controlling Integrated Organ-on-Chip Systems

Open access
Wikswo, J. P., Block, F. E., Cliffel, D. E., Goodwin, C. R., Marasco, C. C., Markov, D. A., McLean, D. L., McLean, J. A., McKenzie, J. R., Reiserer, R. S., Samson, P. C., Schaffer, D. K., Seale, K. T., Sherrod, S. D.·2013·IEEE Transactions on Biomedical Engineering

Abstract

The sophistication and success of recently reported microfabricated organs-on-chips and human organ constructs have made it possible to design scaled and interconnected organ systems that may significantly augment the current drug development pipeline and lead to advances in systems biology. Physiologically realistic live microHuman (μHu) and milliHuman (mHu) systems operating for weeks to months present exciting and important engineering challenges such as determining the appropriate size for each organ to ensure appropriate relative organ functional activity, achieving appropriate cell density, providing the requisite universal perfusion media, sensing the breadth of physiological responses, and maintaining stable control of the entire system, while maintaining fluid scaling that consists of ~5 mL for the mHu and ~5 μL for the μHu. We believe that successful mHu and μHu systems for drug development and systems biology will require low-volume microdevices that support chemical signaling, microfabricated pumps, valves and microformulators, automated optical microscopy, electrochemical sensors for rapid metabolic assessment, ion mobility-mass spectrometry for real-time molecular analysis, advanced bioinformatics, and machine learning algorithms for automated model inference and integrated electronic control. Toward this goal, we are building functional prototype components and are working toward top-down system integration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2013.2244891

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 176

Metadata

Authors
Wikswo, J. P., Block, F. E., Cliffel, D. E., Goodwin, C. R., Marasco, C. C., Markov, D. A., McLean, D. L., McLean, J. A., McKenzie, J. R., Reiserer, R. S., Samson, P. C., Schaffer, D. K., Seale, K. T., & Sherrod, S. D.
Venue
IEEE Transactions on Biomedical Engineering
Published
2013-03
Volume
60
Issue
3
Pages
682-690
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2122927773
Cited by
176
References
8
FWCI
8.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Engineering Challenges for Instrumenting and Controlling Integrated Organ-on-Chip Systems. https://app.cochat.ai/papers/10.1109/tbme.2013.2244891
The paper
Wikswo, J. P., Block, F. E., Cliffel, D. E., Goodwin, C. R., Marasco, C. C., Markov, D. A., McLean, D. L., McLean, J. A., McKenzie, J. R., Reiserer, R. S., Samson, P. C., Schaffer, D. K., Seale, K. T., & Sherrod, S. D. (2013). Engineering Challenges for Instrumenting and Controlling Integrated Organ-on-Chip Systems. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2244891

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.