The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Abstract
We present a novel method for estimating respiratory rate in real time from the photoplethysmogram (PPG) obtained from pulse oximetry. Three respiratory-induced variations (frequency, intensity, and amplitude) are extracted from the PPG using the Incremental-Merge Segmentation algorithm. Frequency content of each respiratory-induced variation is analyzed using fast Fourier transforms. The proposed Smart Fusion method then combines the results of the three respiratory-induced variations using a transparent mean calculation. It automatically eliminates estimations considered to be unreliable because of detected presence of artifacts in the PPG or disagreement between the different individual respiratory rate estimations. The algorithm has been tested on data obtained from 29 children and 13 adults. Results show that it is important to combine the three respiratory-induced variations for robust estimation of respiratory rate. The Smart Fusion showed trends of improved estimation (mean root mean square error 3.0 breaths/min) compared to the individual estimation methods (5.8, 6.2, and 3.9 breaths/min). The Smart Fusion algorithm is being implemented in a mobile phone pulse oximeter device to facilitate the diagnosis of severe childhood pneumonia in remote areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Intrathoracic Pressure on Left Ventricular Performance
Buda, A. J., Pinsky, M. R., Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1979) · New England Journal of Medicine · doi:10.1056/nejm197908303010901 · Cited by 823
An Efficient Algorithm for Spectral Analysis of Heart Rate Variability
Berger, R. D., Akselrod, S., Gordon, D., & Cohen, R. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325789 · Cited by 807
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
ThomsonChavan, J. A. (2006) · Europe PMC (PubMed Central) · doi:10.1136/adc.2006.095844 · Cited by 402
Pneumonia: the forgotten killer of children.
Wardlaw, T., Johansson, E., & Hodge, M. C. (2006) · Cited by 286
Pneumonia - The forgotten killer of children
Unicef, W. (2006) · Cited by 270
Nakajima, K., Tamura, T., & Miike, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00066-6 · Cited by 244
Lovett, P. B., Buchwald, J. M., Stürmann, K., & Bijur, P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.06.016 · Cited by 244
Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 212
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Respiratory sinus arrhythmia and diseases of aging: Obesity, diabetes mellitus, and hypertension
Masi, C. M., Hawkley, L. C., Rickett, E. M., & Cacioppo, J. T. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.07.006 · Cited by 146
Data Fusion for Improved Respiration Rate Estimation
Nemati, S., Malhotra, A., & Clifford, G. D. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2010/926305 · Cited by 117
CapnoBase: Signal database and tools to collect, share and annotate respiratory signals
Karlen, W., Turner, M., Cooke, E., Dumont, G. A., & Ansermino, J. M. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000087887 · Cited by 114
Self-citationNeural network for photoplethysmographic respiratory rate monitoring
Johansson, A. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348427 · Cited by 110
Johansson, A., & Öberg, P. Å. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513264 · Cited by 105
Tarassenko, S. G. F. L. (2007) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1080903 · Cited by 100
Addison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9332-y · Cited by 97
Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications
Karlen, W., Ansermino, J. M., & Dumont, G. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346628 · Cited by 94
Self-citationPulse oximetry: technology to reduce child mortality in developing countries
Duke, T., Subhi, R., Peel, D. A., & Frey, B. (2009) · Annals of Tropical Paediatrics · doi:10.1179/027249309x12467994190011 · Cited by 91
Shelley, K. H., Alian, A. A., Stout, R. G., & Silverman, D. G. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9010-7 · Cited by 86
Nilsson, L. M., Johansson, A., & Kálmán, S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00721.x · Cited by 78
An Algorithm for the Detection of Individual Breaths from the Pulse Oximeter Waveform
Leonard, P. A., Grubb, N. R., Addison, P. S., Clifton, D. A., & Watson, J. N. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-2697-z · Cited by 70
Comparison of respiratory-induced variations in photoplethysmographic signals
Li, J., Jin, J., Chen, X., Sun, W., & Guo, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/3/009 · Cited by 47
Karlen, W., Dumont, G. A., Petersen, C., GOW, J. L., Lim, J. M.-Y., Sleiman, J., & Ansermino, J. M. (2011) · International Conference on Health Informatics · doi:10.5220/0003335204330438 · Cited by 42
Self-citationEstimation of respiratory volumes from the photoplethysmographic signal
Johansson, A. J., & Öberg, Å. (1997) · Cited by 32
Photoplethysmographic measurement of heart and respiratory rates using digital filters
Nakajima, K., TAMURA, T., Ohta, T., Miike, H., & Öberg, P. Å. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.978978 · Cited by 31
Respiratory rate estimation using respiratory sinus arrhythmia from photoplethysmography
Karlen, W., Brouse, C. J., Cooke, E. M., Ansermino, J. M., & Dumont, G. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090282 · Cited by 27
Self-citation
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Metadata
- Authors
- Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-07
- Volume
- 60
- Issue
- 7
- Pages
- 1946-1953
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2124106073
- Cited by
- 485
- References
- 28
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.