The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Ingestible Sensor for Measuring Medication Adherence
Open accessAbstract
In this paper, we describe the design and performance of the first integrated-circuit microsensor developed for daily ingestion by patients. The ingestible sensor is a device that allows patients, families, and physicians to measure medication ingestion and adherence patterns in real time, relate pharmaceutical compliance to important physiologic metrics, and take appropriate action in response to a patient's adherence pattern and specific health metrics. The design and theory of operation of the device are presented, along with key in-vitro and in-vivo performance results. The chemical, toxicological, mechanical, and electrical safety tests performed to establish the device's safety profile are described in detail. Finally, aggregate results from multiple clinical trials involving 412 patients and 5656 days of system usage are presented to demonstrate the device's reliability and performance as part of an overall digital health feedback system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osterberg, L., & Blaschke, T. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050100 · Cited by 7,974
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
An ingestible bacterial-electronic system to monitor gastrointestinal health
Mimee, M., Nadeau, P., Hayward, A., Carim, S., Flanagan, S., Jerger, L., Collins, J., McDonnell, S., Swartwout, R., Citorik, R. J., et al. (2018) · Science · doi:10.1126/science.aas9315 · Cited by 606
Sim, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1806949 · Cited by 491
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
An Overview of Patient’s Health Status Monitoring System Based on Internet of Things (IoT)
Kadhim, K. T., Alsahlany, A. M., Wadi, S. M., & Kadhum, H. T. (2020) · Wireless Personal Communications · doi:10.1007/s11277-020-07474-0 · Cited by 267
How 5g wireless (and concomitant technologies) will revolutionize healthcare?
Latif, S., Qadir, J., Farooq, S., & Imran, M. (2017) · Future Internet · doi:10.3390/fi9040093 · Cited by 219
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Cohen, A. B., & Mathews, S. C. (2018) · Digital Biomarkers · doi:10.1159/000492396 · Cited by 24
Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period
Profit, D., Rohatagi, S., Zhao, C., Hatch, A., Docherty, J. P., & Peters-Strickland, T. S. (2016) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.16m10643 · Cited by 24
A scoping review of artificial intelligence-enabled wearables for medication adherence
Chen, Y., Zhao, H., Xu, R., Li, Y., Cai, S., & Hu, Y. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-03246-5
Metadata
- Authors
- Hafezi, H., Robertson, T. L., Moon, G. D., Au-Yeung, K.-Y., Zdeblick, M. J., & Savage, G. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-01
- Volume
- 62
- Issue
- 1
- Pages
- 99-109
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2043136009
- Cited by
- 226
- References
- 1
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.