Depth Sensing for Improved Control of Lower Limb Prostheses
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Powered lower limb prostheses have potential to improve the quality of life of individuals with amputations by enabling all daily activities. However, seamless ambulation mode recognition is necessary to achieve this goal and is not yet a clinical reality. Current intent recognition systems use mechanical and EMG sensors to estimate prosthesis and user status. We propose to complement these systems by integrating information about the environment obtained through the depth sensing. This paper presents the design, characterization, and the early validation of a novel stair segmentation system based on Microsoft Kinect. Static and dynamic tests were performed. A first experiment showed how the resolution of the depth camera affects the speed and the accuracy of segmentation. A second test proved the robustness of the algorithm to different staircases. Finally, we performed an online walking test with the stair segmentation and related measures recorded online at >5 frames/s. Experimental results show that the proposed algorithm allows for an accurate estimate of distance, angle of intersection, number of steps, stair height, and stair depth for a set of stairs in the environment. The online test produced an estimate of whether the individual was approaching stairs in real time with approximately 98.8% accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nearest neighbor pattern classification
Cover, T., & Hart, P. (1967) · IEEE Transactions on Information Theory · doi:10.1109/tit.1967.1053964 · Cited by 16,936
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Self-citationA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Cited by
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Whole body awareness for controlling a robotic transfemoral prosthesis
Parri, A., Martini, E., Geeroms, J., Flynn, L., Pasquini, G., Crea, S., Molino Lova, R., Lefeber, D., Kamnik, R., Munih, M., et al. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00025 · Cited by 29
“Recent advancements have implemented environment awareness controller by means of depth or infrared sensing (Zhang et al., 2011; Krausz et al., 2015; Liu et al., 2016) to detect different terrains; nevertheless, strong reliance on the sensor’s line of sight is one of the main limitations of such approach.”
Background
Metadata
- Authors
- Krausz, N. E., Lenzi, T., & Hargrove, L. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-11
- Volume
- 62
- Issue
- 11
- Pages
- 2576-2587
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1914429872
- Cited by
- 115
- References
- 4
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.