Cited by 135Neuroscience and Neural EngineeringEEG and Brain-Computer InterfacesMuscle activation and electromyography studies

Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies

Open access
Normann, Richard A, Fernandez, Eduardo·2016·Journal of Neural Engineering

Abstract

This paper briefly describes some of the recent progress in the development of penetrating microelectrode arrays and highlights the use of two of these devices, Utah electrode arrays and Utah slanted electrode arrays, in two therapeutic interventions: recording volitional skeletal motor commands from the central nervous system, and recording motor commands and evoking somatosensory percepts in the peripheral nervous system (PNS). The paper also briefly explores other potential sites for microelectrode array interventions that could be profitably pursued and that could have important consequences in enhancing the quality of life of patients that has been compromised by disorders of the central and PNSs.

AI snapshot

Written from the paper’s full text.

TL;DR

This review describes penetrating microelectrode array technologies, especially the Utah Electrode Array (UEA) and Utah Slanted Electrode Array (USEA), and surveys their actual and proposed clinical applications in the CNS and PNS. It emphasizes that UEA/USEA systems can record and stimulate neural activity with high spatial selectivity, but that long-term biocompatibility and device lifetime remain major barriers to routine clinical use.

Key findings

  • The UEA consists of 100 silicon microneedles, each 1.5 mm long, projecting from a 4 mm × 4 mm × 0.2 mm substrate; tips are iridium oxide-coated, and the array is insulated with parylene. The USEA has electrode lengths varying linearly from 0.5 to 1.5 mm, so for a 400 µm-spaced USEA no fiber in an implanted nerve is farther than 200 µm from an active electrode tip.
  • In human amputee work, USEAs implanted in severed median and/or ulnar nerves recorded volitional motor intent; up to 13 separate finger/hand movements were decoded with regressions greater than 0.5, and a single finger movement could be controlled with as few as ten training trials. Two 100-electrode USEAs implanted for four weeks in the residual ulnar and median nerves of a 50-year-old male amputated 21 years earlier evoked localized sensory percepts in the phantom hand.
  • The review cites responsive neurostimulation for drug-resistant epilepsy as achieving median seizure reductions of 44% at one year and 53% at two years post-implant. It also discusses VNS for epilepsy/depression, diaphragm pacing, pudendal nerve modulation, visual cortex stimulation, and auditory midbrain/auditory nerve stimulation as future or emerging applications.
  • The HD-USEA has electrodes spaced at 200 µm, giving 25 electrodes mm⁻²; implanted in rat sciatic nerve, it produced transient impairment in wheel running, with normal levels observed two weeks post-implantation.

Methods

  • Narrative review of penetrating neural interface technologies and clinical applications, with particular focus on UEA and USEA architectures.
  • Synthesizes prior animal and human studies, including rat sciatic nerve implants, human amputee USEA recordings/stimulation, epilepsy microelectrode research, and neuroprosthetic applications.
  • No systematic search strategy, meta-analysis, or new primary data are described; the main analysis is qualitative synthesis of cited literature and device examples.

Limitations

  • The paper states that most penetrating microelectrode arrays currently have maximum in vivo lifetimes of several months or a few years, and that much work is needed on long-term biocompatibility, spike sorting, computational algorithms, stimulation protocols, and wireless links to minimize infections from percutaneous lead wires.
  • The paper states that implantation inevitably breaches the blood-brain barrier and causes accumulation of reactive microphages and eventual encapsulation, leading to gradual deterioration in single-unit recording quality and fewer recording electrodes over time; USEA implantation in rat sciatic nerve caused transient behavioral deficits that returned to normal within days to weeks.
  • Evident from the text: as a narrative review, it does not systematically assess evidence quality or risk of bias, and many clinical applications discussed are described as preliminary, hypothetical, or requiring further studies before clinical adoption.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1088/1741-2560/13/6/061003

Cites

129 of 129 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

0 of 114 cited sources checked · 0 supported · 0 flagged

  • Findingcitation

    In lattice electrodes, the fibrotic response around the larger supporting framework is much larger than the response around the silicon filament.

    “These lattice electrodes have been used in anatomical experiments, where it has been shown that the fibrotic response around the larger supporting framework is much larger than the response around the silicon filament (Skousen et al 2011)).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Skousen et al 2011

      Not checked in the free run.

  • Findingcitation

    In rats whose sciatic nerves were implanted with USEAs, wheel-running, toe-spread, and paw withdrawal reflex experiments showed transient deficits that returned to normal within days to weeks.

    “Consistent with this breach of the blood brain barrier, behavioral wheel-running, toe-spread and paw withdrawal reflex experiments in rats whose sciatic nerves were implanted with USEA's manifested transient deficits, but these indices returned to normal levels within days to weeks post implantation (Wark et al 2014).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Wark et al 2014

      Not checked in the free run.

  • Findingcitation

    When hippocampal and spinal cord cells were cultured on boron-doped diamond substrates, these materials appear to foster neurite proliferation.

    “When hippocampal and spinal cord cells were cultured on boron-doped diamond substrates, these materials appear to foster neurite proliferation.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Piret et al 2015

      Not checked in the free run.

  • Findingcitation

    Blood-brain-barrier compromise from implantation promotes accumulation of red blood cells, hemosiderin, and reactive microphages near implanted electrodes.

    “This is a problem with all penetrating microelectrode designs, and it promotes the accumulation of red blood cells, hemosiderin and reactive microphages in the vicinity of many of the implanted electrodes”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites House et al 2006

      Not checked in the free run.

    • cites Biran et al 2007

      Not checked in the free run.

  • Findingcitation

    Accelerating the array to a high velocity during insertion achieves complete insertion of all electrodes in under 200 ms because of the viscoelastic properties of neural tissues.

    “The viscoelastic properties of the neural tissues are such that complete insertion of all electrodes is achieved in under 200 ms.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Rousche and Normann 1992

      Not checked in the free run.

  • May combine two claims. 48
  • Classified as probably not a substantial claim. 10
  • May combine two claims.

    Findingcitation

    Silicon carbide has been shown to offer enhanced passivation of electrodes and electronic circuitry in saline environments and may provide long-term mechanical stability in vivo.

    “Silicon carbide is one such material that has been shown to offer enhanced passivation of electrodes and electronic circuitry when tested in saline environments and may provide long-term mechanical stability in vivo (Faßbender et al 2000).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Faßbender et al 2000

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    Attempting to push a UEA into the brain tends to compress the brain surface, and only perimeter electrodes implant, and only to a limited depth.

    “attempting to push the array into the brain only tends to compress the surface of the brain; and only electrodes around the perimeter of the array experience implantation, and only to a limited depth.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Rousche and Normann 1992

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    PEDOT is a polymeric conductor that has been shown to achieve impedance reductions, but protecting this coating from shear forces during electrode insertion into neural tissues is unresolved.

    “PEDOT, is a polymeric conductor that has been shown to achieve such impedance reductions, but protecting this coating from the shear forces associated with electrode insertion into neural tissues is an unresolved problem (Frost et al 2012).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Frost et al 2012

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    Implantation of a USEA into a peripheral nerve impales some vessels, causing a breach of the blood brain barrier and local accumulation of reactive microphages around the implanted electrodes.

    “The spatial organization of the vasculature of the peripheral nerves cannot be predicted prior to implantation, and some vessels are likely to be impaled by the penetrating electrodes, causing a breach of the blood brain barrier and a local accumulation of reactive microphages around the implanted electrodes (Christensen et al 2014, Wark et al 2014).”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites Christensen et al 2014

      Not checked in the free run.

    • cites Wark et al 2014

      Not checked in the free run.

    • Rests on an assumption: The spatial organization of the vasculature of peripheral nerves cannot be predicted prior to implantation.
  • May combine two claims.

    Findingnone given

    Several studies have shown that the ability of patients with tetraplegia to plan and imagine movements is usually intact and that it is possible to bypass damaged neural pathways with penetrating microelectrode arrays that record brain activity reflecting motor intention.

    “Several studies have shown that the ability of patients with tetraplegia to plan and imagine movements is usually intact and that it is possible to bypass the damaged neural pathways with the use of penetrating microelectrode arrays that record the brain activity that reflects the individual's motor intention.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: There is a causative correlation between spatio-temporal neural activity patterns in motor cortex and a paralyzed subject's intent to perform particular volitional movements.
  • May combine two claims.

    Findingcitation

    High density Utah slanted electrode arrays implanted in rat sciatic nerves caused transient impairment of peripheral nerve function, but normal wheel running was observed two weeks post-implantation.

    “These high density electrode arrays have been implanted in rat sciatic nerves, and although wheel running measurements have shown a transient impairment of peripheral nerve function, normal levels of wheel running were observed in two weeks post-implantation (Wark et al 2014).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Wark et al 2014

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    Sensorized hand prostheses with up to 23 degrees-of-freedom are presently available, or will soon become available.

    “sensorized hand prostheses with up to 23 degrees-of-freedom are presently available, or will soon become available (Krausz et al 2015, Veer 2015).”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites Krausz et al 2015

      Not checked in the free run.

    • cites Veer 2015

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    Important limitations of the myoelectric approach include difficulty in recording suitable EMG signals and a shortage of information for control of multiple functions.

    “However there are important limitations of this approach such as the difficulty in recording suitable EMG signals and the shortage of information for control of multiple functions (Schultz and Kuiken 2011).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Schultz and Kuiken 2011

      Not checked in the free run.

  • May combine two claims.

    Findingcitation

    Patients with motor function impairments can use signals from motor regions of their brains to control a cursor on a screen or steer a robotic arm to reach, grasp, and manipulate an object or a glass.

    “Thus patients with motor function impairments can use the signals from the motor regions of their brains to, for example, control a cursor on a screen so that they can efficiently interact with a computer, or, as shown in figure 8, to steer a robotic arm to reach out, grasp and manipulate an object or a glass in order to take a drink (Hochberg et al 2012, Collinger et al 2013).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Hochberg et al 2012

      Not checked in the free run.

    • cites Collinger et al 2013

      Not checked in the free run.

    • The authors state this as an assumption: There is a causative correlation between spatio-temporal neural activity patterns in motor cortex and a paralyzed subject's intent to perform particular volitional movements.
  • May combine two claims.

    Findingown data

    Most electrodes evoked a tingling sensation, while other electrodes evoked percepts of brushing along a finger or discrete proprioceptive percepts such as finger flexing.

    “Most electrodes evoked a tingling sensation, but other electrodes evoked the percepts of 'brushing along a finger' or discrete proprioceptive percepts such as the flexing of a finger.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingcitation

    USEAs can be implanted in severed peripheral nerves above the site of amputation, and the tips of the implanted electrodes will be distributed throughout the fascicles of the implanted nerves.

    “USEAs can be implanted in severed peripheral nerves above the site of amputation, and the tips of the implanted electrodes will be distributed throughout the fascicles of the implanted nerves (Branner et al 2004, Wark et al 2014).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Branner et al 2004

      Not checked in the free run.

    • cites Wark et al 2014

      Not checked in the free run.

  • May combine two claims.

    Findingreasoning

    Only a subset of implanted electrodes evoked sensory percepts because many did not abut sensory fibers.

    “As many of the implanted electrodes did not abut sensory fibers, currents injected via only a subset of electrodes evoked these sensory percepts”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Continuous encapsulation produces an ever-growing barrier between electrode tips and surrounding neurons, causing single unit recording quality to deteriorate and the number of electrodes recording single units to decrease.

    “This continuous encapsulation process produces an ever growing barrier between the electrode tips and the surrounding neurons, and single unit recording quality gradually deteriorates and the number of electrodes that successfully record single units also gradually decreases.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    For a 400 micron spaced USEA, no fiber in the nerve is further than 200 microns from an active electrode tip, and most fibers are much closer.

    “Because of the gradient in electrode lengths, for a 400 micron spaced USEA, no fiber in the nerve is further than 200 microns from an active electrode tip, and most fibers are much closer.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Inserting a complex three-dimensional structure into the highly vascularized cortex inevitably impales capillaries and compromises the blood-brain barrier.

    “The cortical tissues are highly vascularized, so it is impossible to insert such a complex three-dimensional structure into the cortex without impaling capillaries, causing the blood-brain-barrier to be compromised by the implantation process.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationcitation

    Penetrating microelectrode arrays implanted in paralyzed subjects allow unprecedented access to CNS neurons and provide insights into neural mechanisms of motor control that are only marginally available from surface field potentials.

    “Penetrating microelectrode arrays, implanted in paralyzed subjects allow unprecedented access to the neurons of the CNS and provide insights into the neural mechanisms of motor control which is only marginally available from surface field potentials (Hatsopoulos and Donoghue 2009).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Hatsopoulos and Donoghue 2009

      Not checked in the free run.

    • The authors state this as an assumption: There is a causative correlation between spatio-temporal neural activity patterns in motor cortex and a paralyzed subject's intent to perform particular volitional movements.
  • May combine two claims.

    Interpretationreasoning

    The UEA's thin substrate and lead wires give a very thin super-cortical profile when implanted in cortical tissue, allowing the skull of experimental animals to be closed after implantation.

    “The 0.2 mm thick substrate and lead wires of the UEA provides a very thin super-cortical profile when the UEA is implanted in cortical tissue, allowing the skull of experimental animals to be closed after implantation.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationnone given

    As penetrating electrodes become thinner, at some point they will not have the mechanical strength to withstand insertion without buckling and breaking.

    “However, as the penetrating electrodes become thinner, at some point they will not have the mechanical strength to withstand insertion without buckling and breaking.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Interpretationnone given

    Fabrication processes and materials have yet to be discovered that passivate devices for the years required in clinical devices.

    “Fabrication processes and materials have yet to be discovered that passivate the devices for the years that will be required in clinical devices.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.

    Interpretationnone given

    Lower electrode impedances allow larger currents to be passed for a given electrode polarization and reduce noise in single- and multi-unit recordings.

    “Lower electrode impedances allow larger currents to be passed via the electrode for a given electrode polarization, and reduce the noise in the single-and multi-unit recordings made with these devices.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisenone given

    Present day upper limb prostheses are myoelectrically controlled, with EMG electrodes built into the cuff of the wearer's prosthesis.

    “Traditional myoelectrically controlled prostheses take advantage of the neural information provided by muscle contractions and present day upper limb prostheses are myoelectrically controlled, with electromyography (EMG) electrodes built into the cuff of the wearer's prosthesis.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationnone given

    Individuals with extant forearms achieve highly dexterous control of their hands and fingers partly because of somatosensory and tactile feedback from the fingers, muscles, and skin of the intact hand/forearm.

    “Further, individuals with extant forearms are able to achieve highly dexterous control of their hands and fingers, in part because of somatosensory and tactile feedback originating in the fingers, muscles and skin of his/her intact hand/ forearm.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Severed peripheral nerves above the level of amputation are a more direct site for neural control signals and have already been used for neural control of external devices.

    “A more direct site for neural control signals are the severed peripheral nerves above the level of the amputation, and this site has been already used for neural control of external devices (Dhillon et al 2004, Horch et al 2011).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Dhillon et al 2004

      Not checked in the free run.

    • cites Horch et al 2011

      Not checked in the free run.

  • May combine two claims.

    Interpretationreasoning

    The USEA can selectively contact small groups of axons within a nerve fascicle and could allow patients with tetraplegia to regain better control of hand movements for greater independence in daily activities.

    “This penetrating neural interface can selectively contact small groups of axons within a nerve fascicle and could allow patients with tetraplegia to regain a better control of hand movements in order to achieve a greater measure of independence in daily activities.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Intervening in the peripheral nervous system could offer many opportunities to restore sensory and/or motor function to those who have lost these functions.
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Recent advances in hand prostheses include devices with multiple degrees of freedom and sensors on fingers and joints.

    “Recent notable advances in the field of hand prostheses have included designing devices with multiple degrees of freedom and with various sensors located on the fingers and joints (Krausz et al 2015, Veer 2015).”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites Krausz et al 2015

      Not checked in the free run.

    • cites Veer 2015

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Up to 13 separate finger or hand movements have been decoded from neural activity, with correlations between targeted and decoded movements exceeding 0.5.

    “up to 13 separate finger/hand movements have been decoded with regressions between the targeted movements and the decoded movements greater than 0.5 (Davis et al 2016).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Davis et al 2016 source

      Not checked in the free run.

  • May combine two claims.

    Interpretationreasoning

    Electrodes abutting motor fibers can record neural activity evoked by the desire of the amputee to flex his or her elbow, whereas other electrodes can record the desire to flex or extend the wrist.

    “The electrodes abutting motor fibers can be used to record neural activity evoked by the desire of the amputee to flex his or her elbow, whereas other electrodes can record, for example, the desire to flex or extend the wrist.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    The spatial-temporal neural activity pattern associated with intending to move a particular finger is robust and somewhat unique because severed motor nerves continue to send motor commands to missing muscles in the phantom forearm or hand.

    “Because the severed motor nerves still are transmitting motor commands to missing muscles in the phantom forearm/hand, the spatial-temporal neural activity pattern associated with the intent to move a particular finger is robust and somewhat unique.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Severed motor nerves continue to transmit motor commands to missing muscles in the phantom forearm or hand.
  • May combine two claims.

    Interpretationcitation

    Direct connection of a prosthetic limb to the PNS can be safely implanted into humans and could provide a high degree of control of the actuators in prosthetic limbs.

    “This form of direct connection of the prosthetic limb to the PNS can be safely implanted into humans (Normann 2007) and could provide a high degree of control of the actuators in the prosthetic limbs (Clark et al 2014).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Normann 2007

      Not checked in the free run.

    • cites Clark et al 2014

      Not checked in the free run.

    • Rests on an assumption: Intervening in the peripheral nervous system could offer many opportunities to restore sensory and/or motor function to those who have lost these functions.
  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationreasoning

    Selective recording of volitionally evoked neural activity extends to electrodes selective for individual digit extension and flexion.

    “This selective recording of volitionally evoked neural activity would extend to electrodes selective for individual digit extension and flexion”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Decoding these activity patterns is straightforward and requires only a minimal number of training sessions before subjects can control a robotic hand with volitional thoughts.

    “As such, decoding these activity patterns is straightforward and requires only a minimal number of training sessions before the subjects are able to control the robotic hand with his/her volitional thoughts.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    The aim of electrical brain stimulation is to shorten ictal phases by modulating the epileptogenic zone.

    “The aim of electrical brain stimulation is to shorten ictal phases by modulating the epileptogenic zone (Fisher and Velasco 2014).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Fisher and Velasco 2014

      Not checked in the free run.

  • May combine two claims.

    Interpretationreasoning

    Most clinical applications described are still at very preliminary stages, but penetrating microelectronic devices are beginning to be considered as viable therapies for a broad range of patients with injury or disease of the nervous system.

    “Although most of the clinical applications described below are still at very preliminary stages, these penetrating microelectronic devices are beginning to be considered as viable therapies for a broad range of patients with injury or disease of the nervous system.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Some electrodes in a USEA implanted in a severed nerve abut afferent motor fibers and others abut efferent sensory fibers.

    “Some electrodes abut afferent motor fibers and others abut efferent sensory fibers.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    The left vagus nerve is stimulated rather than the right because the right plays a role in cardiac function and stimulating it could have negative cardiac effects.

    “The left vagus nerve is stimulated rather than the right because the right plays a role in cardiac function so that stimulating it could have negative cardiac effects (George et al 2000).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites George et al 2000

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    VNS stimulation turns off the immune/inflammatory response, improves left ventricular function and positively affects other key drivers of heart failure progression.

    “VNS stimulation turns off the immune/inflammatory response, improves left ventricular function and positively affects other key drivers of heart failure progression (De Ferrari et al 2011, Sabbah 2011).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites De Ferrari et al 2011

      Not checked in the free run.

    • cites Sabbah 2011

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Most vagus nerve fibers originate from neurons in the nodose ganglion and project mostly to the nucleus of the solitary tract, with connections also to the medial reticular formation of the medulla, dorsal motor nucleus of the vagus, area postrema and nucleus cunneatus.

    “Most of the fibers originate from neurons in the nodose ganglion and send their projections mostly to the nucleus of the solitary tract, but there are also connections to the medial reticular formation of the medulla, the dorsal motor nucleus of the vagus, the area postrema and the nucleus cunneatus (Rutecki 1990).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Rutecki 1990

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Clinical studies have shown that diaphragm pacing is a stable and effective method of long-term respiratory support in high-level cervical spinal cord injury patients, improving survival length and quality of life.

    “Clinical studies have shown that diaphragm pacing is a stable and effective method of long-term respiratory support in high-level cervical spinal cord injury patients, improving the length of survival and the quality of life of these patients (Romero et al 2012, Posluszny et al 2014).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Romero et al 2012

      Not checked in the free run.

    • cites Posluszny et al 2014

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The UEA has been used in research with epilepsy patients, and these studies demonstrated that it can record cortical circuit dynamics with excellent spatial and temporal resolution.

    “In this context, the UEA has been recently used in research with epilepsy patients (Truccolo et al 2011, Weiss et al 2013, Weiss et al 2013, Kellis et al 2016) and the results of these studies have demonstrated that this penetrating microelectrode array is able to record the dynamics of the cortical circuits with excellent resolution in space and time.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites Truccolo et al 2011

      Not checked in the free run.

    • cites Weiss et al 2013

      Not checked in the free run.

    • cites Kellis et al 2016

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Diaphragm pacing stimulation delays the need for ventilators and improves sleep in some patients with amyotrophic lateral sclerosis, increasing their survival.

    “Furthermore diaphragm pacing stimulation delays the need for ventilators and improves sleep in some patients with amyotrophic lateral sclerosis, increasing their survival (Onders et al 2009, Gonzalez-Bermejo et al 2012).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Onders et al 2009

      Not checked in the free run.

    • cites Gonzalez-Bermejo et al 2012

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Selective stimulation of these neural fibers can improve cardiac autonomic control and significantly attenuate heart failure.

    “Consequently, selective stimulation of these neural fibers can improve cardiac autonomic control and significantly attenuate heart failure (Sabbah 2011).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Sabbah 2011

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Several researchers have proposed that VNS has potential for treating other CNS conditions including involuntary movement disorders, depression, Alzheimer's disease, migraine and neuropsychiatric disorders.

    “Moreover, several researches have proposed that VNS also has the potential for treatment of other clinical conditions affecting the CNS including involuntary movement disorders, depression, Alzheimer's disease, migraine and neuropsychiatric disorders (Groves and Brown 2005).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Groves and Brown 2005

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Cuff electrodes used to record bladder afferent nerve signals have drawbacks of low signal-to-noise ratios and interference from non-bladder activity.

    “Cuff electrodes have been conventionally used to record the activity of bladder afferent nerve signals, but they present the drawback of low signal-tonoise ratios and interference from non-bladder activity (Kent and Grill 2013, Lee et al 2015).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Kent and Grill 2013

      Not checked in the free run.

    • cites Lee et al 2015

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Adverse effects associated with VNS implantation and stimulation include hoarseness, cough, dyspnea, pain, paresthesia, nausea and headache, with hoarseness and dyspnea more likely on high stimulation than low stimulation.

    “However there are some adverse effects associated with implantation and stimulation such as hoarseness, cough, dyspnea, pain, paresthesia, nausea and headache, with hoarseness and dyspnea more likely to occur on high stimulation than low stimulation (Panebianco et al 2015).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Panebianco et al 2015

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Intermittent or periodic stimulation with predetermined patterns and intensity tends to decrease anti-epileptic efficacy over time and cannot respond to changes in clinical symptoms or underlying disease.

    “However clinical tests have revealed that intermittent or periodic stimulation with predetermined patterns and intensity tends to decrease its anti-epileptic efficacy over time and, furthermore, is not able to respond to changes in the patient's clinical symptoms or in the underlying disease (Sun and Morrell 2014).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Sun and Morrell 2014

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Responsive neurostimulation can truncate individual seizures at stimulus onset, reducing overall seizure frequency by 50%-60%.

    “This paradigm, called responsive neurostimulation is able to truncate individual seizures at the onset of the stimulus, reaching a reduction of 50%-60% of the overall seizure frequency (Sun et al 2008).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Sun et al 2008

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The median percent reduction in seizures with the RNS System was 44% at one year and 53% at two years postimplant compared with baseline.

    “The median percent reduction in seizures was 44% at one year and 53% at two years postimplant compared with baseline (Fisher and Velasco 2014).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Fisher and Velasco 2014

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Chronic stimulation for one year resulted in more than 90% reductions in seizure frequency while preserving motor function.

    “Chronic stimulation for one year resulted in more than 90% reductions in seizure frequency while preserving motor function”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Velasco et al 2009

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Microelectrode arrays such as USEA or HD-USEA can selectively record pudendal nerve activity corresponding to genitourinary stimuli and can also stimulate to restore urinary function.

    “In this way microelectrodes arrays such as the USEA or the HD-USEA can selectively record neural activity in the pudendal nerves that correspond to various genitourinary stimuli, such as bladder filling or distention-evoked bladder contractions, and furthermore, can also work as stimulation electrodes to restore urinary function (Wark et al 2014, Wark et al 2015).”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Wark et al 2014

      Not checked in the free run.

    • cites Wark et al 2015

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Cochlear implant research has arguably been the most successful in restoring lost sensory function and has become a viable therapeutic option for many profoundly deaf patients.

    “In terms of restoring lost sensory function, cochlear implant research has arguably been the most successful and has been translated into a viable therapeutic option for many profoundly deaf patients (Pena et al 2004).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Pena et al 2004

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Retinal diseases frequently reduce visual acuity and result in non-curable blindness, and several groups are developing prostheses for the remaining healthy retina, optic nerve and LGN.

    “Since retinal diseases frequently reduce visual acuity and result in non-curable blindness, several groups worldwide are working on the development of various prostheses designed to interact with the remaining healthy retina (Stingl et al 2013, Chuang et al 2014, Picaud and Sahel 2014, Stronks and Dagnelie 2014), optic nerve (Brelen et al 2010) and LGN (Vurro et al 2014).”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites Stingl et al 2013

      Not checked in the free run.

    • cites Chuang et al 2014

      Not checked in the free run.

    • cites Picaud and Sahel 2014

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The output neurons of the eye, ganglion cells, often degenerate in many retinal blindnesses, so retinal, optic nerve or LGN prostheses are not expected to help blindness caused by glaucoma or optic atrophy or diseases of visual pathways.

    “However the output neurons of the eye, the ganglion cells, often degenerate in many retinal blindnesses (Marc et al 2008), and therefore a retinal, optic nerve or even a LGN prosthesis are not expected to be helpful for blindness caused by glaucoma or optic atrophy nor for diseases of the visual pathways.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Marc et al 2008

      Not checked in the free run.

  • May combine two claims.

    Interpretationcitation

    Electrodes implanted near the occipital pole or in extrastriate areas could elicit patterned perceptions and provide a limited but useful sense in blind subjects.

    “and suggest that electrodes implanted near the occipital pole or in extrastriate areas could be able to elicit patterned perceptions and provide a limited but useful sense in blind subjects (Fernandez et al 2015).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Fernandez et al 2015

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Single-shank devices cannot activate neurons across the three-dimensional structure of the inferior colliculus with sufficient spatial and temporal resolution and do not achieve performance levels comparable to cochlear implants.

    “Thus, these single shank devices cannot activate neurons across the three-dimensional structure of the inferior colliculus with sufficient spatial and temporal resolution and do not achieve performance levels comparable to cochlear implants (Lim et al 2009).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Lim et al 2009

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).

    Interpretationnone given

    Neural plasticity of the visual cortex should allow ever-improving correlation between the physical world and evoked phosphenes.

    “Furthermore, the neural plasticity of the visual cortex should allow ever-improving correlation between the physical world and evoked phosphenes.”
    Quote in the paperNot a substantial claim
55 of 55
  • The paper relies on this without support.

    New penetrating microelectrode array technologies may enable therapeutic interventions that mitigate morbidities from diseases and traumatic injuries of the central and peripheral nervous systems.

    “With the advent of new penetrating microelectrode array technologies, a variety of new therapeutic interventions may become possible that can mitigate many of the morbidities that are associated with diseases and traumatic injuries to the central and peripheral nervous systems (CNS and PNS).”
  • The paper relies on this without support.

    Information processing in the nervous system involves spatially and temporally concerted activity of large groups of neurons.

    “Information processing in the nervous system involves the spatially and temporally concerted activity of large groups of neurons, and this has motivated the development of more complex neural interfaces that can interact selectively with larger groups of neurons in targeted brain regions.”
  • The authors state this as an assumption.

    There is a causative correlation between spatio-temporal neural activity patterns in motor cortex and a paralyzed subject's intent to perform particular volitional movements.

    “The premise underlying this work is that there is a causative correlation between the spatio-temporal neural activity pattern in motor cortex and a paralyzed subject's intent to perform particular volitional movements (even though the spinal cord injury blocks the execution of these commands).”
  • The paper relies on this without support.

    At present, biologically reconnecting damaged neural pathways is not feasible.

    “Although it may someday be possible to biologically reconnect damaged neural pathways, at present this is not feasible so that these patients lose, inevitably, the control of their skeletal muscles.”
  • The paper relies on this without support.

    Intervening in the peripheral nervous system could offer many opportunities to restore sensory and/or motor function to those who have lost these functions.

    “When considering potential clinical neuroengineering applications of penetrating microelectrode array technology, it becomes clear that the ability to intervene in the PNS could offer many opportunities to restore sensory and/or motor function to those who have lost these functions.”
  • The paper relies on this without support.

    The spatial organization of the vasculature of peripheral nerves cannot be predicted prior to implantation.

    “The spatial organization of the vasculature of the peripheral nerves cannot be predicted prior to implantation, and some vessels are likely to be impaled by the penetrating electrodes”
  • The paper relies on this without support.

    Once damaged, the adult mammalian nervous system is capable of little functional regeneration.

    “Once damaged, the adult mammalian nervous system is capable of little functional regeneration.”
  • The paper relies on this without support.

    About 30% of epilepsy patients have drug-resistant epilepsy and continue to suffer seizures despite using two or more anti-seizure medications.

    “In many cases seizures are well controlled with currently available anti-epileptic drugs but about 30% of the patients have drug-resistant epilepsy, which means that they continue to suffer from seizures despite using two or more anti-seizure medications.”
  • The paper relies on this without support.

    Approximately two-thirds of people with drug-resistant epilepsy are not candidates for surgical resections for various reasons, including seizure location and other health conditions.

    “However approximately two-thirds of people with drug-resistant epilepsy are not candidates for surgical resections for various reasons, including the location of the seizures and other health conditions.”
  • The paper relies on this without support.

    Severed motor nerves continue to transmit motor commands to missing muscles in the phantom forearm or hand.

    “Because the severed motor nerves still are transmitting motor commands to missing muscles in the phantom forearm/hand”
  • The paper relies on this without support.

    Prior to amputation, a single motor nerve innervates a motor unit, and this targeting appears to remain unchanged after amputation.

    “prior to amputation, a single motor nerve innervates a motor unit, and this targeting appears to remain unchanged after amputation.”
11 of 11

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The results suggest that silicon-based, penetrating microelectrode arrays could provide the stability required in a clinical device.

    “The results therefore suggest that silicon-based, penetrating microelectrode arrays could provide the stability required in a clinical device (11, 32-34) but further investigations in more subjects and over a longer period of time are needed.”

    From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [11]

    Section 2.5 describes silicon as a mechanically strong substrate and says silicon carbide may provide long-term mechanical stability in vivo. But it also says materials have not yet been found that protect arrays for the years required in clinical devices. The Conclusions report limited current lifetimes and say further work is needed, so the source supports the possibility, not evidence that silicon-based arrays provide the required clinical stability. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • All these factors place high demands on the long-term function of any intracortical electrode and impose unique constraints for the materials, packaging, and insulation of the electronics.

    “All of these factors place high demands on the long-term function of any intracortical electrode and also impose unique constrains for the materials, packaging, and insulation of the electronics (Normann and Fernandez, 2016).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Figure 10 dot size represents two different quantities

    Minor

    The text says dot diameter represents the spatial size of each evoked percept, while the figure caption says dot size represents percept amplitude.

1 of 1

Cites

Flagged first, then by citations

Research works printed but not linked: 9

  1. Chapin J K, 1998, CNS*1998
  2. Fernandez E, 2015, Invest. Opthalmol. Vis. Sci., 56, 777
  3. Kent A R, 2013, J. Neural Eng., 10
  4. Marc R E, 2008, Mol. Vis., 14, 782
  5. Neves H P, 2007, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2007, 6443
  6. Panebianco M, 2015, Cochrane Database Syst. Rev., 4
  7. Prasad A, 2012, J. Neural Eng., 9
  8. Wark H A, 2014, J. Neural Eng., 11
  9. Wark H A, 2013, J. Neural Eng., 10

Cited by

Sorted by citations

Authors
Normann, R. A., & Fernandez, E.
Affiliations
University of Utah (US)
Corresponding author
Normann, Richard A
Venue
Journal of Neural Engineering
Published
2016-10-20
Volume
13
Issue
6
Pages
061003
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2539189254
Cited by
135
References
129
Citations by year
2026: 8 · 2025: 15 · 2024: 17 · 2023: 14 · 2022: 15 · 2021: 15 · 2020: 15 · 2019: 18 · 2018: 12 · 2017: 5 · 2016: 1
FWCI
1.31
Type
journal article
Language
en
Open access
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
Utah electrode array, microelectrode arrays, somatosensory feedback, peripheral nervous system, central nervous system disorders, neuroprosthetics, quality of life
MeSH terms
Artificial Limbs, Electrodes, Implanted, Humans, Microelectrodes, Prosthesis Design, Neural Prostheses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-08.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-08.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review